A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson's disease. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson's disease. Issue 1 (December 2016)
- Main Title:
- A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson's disease
- Authors:
- Godinho, Catarina
Domingos, Josefa
Cunha, Guilherme
Santos, Ana
Fernandes, Ricardo
Abreu, Daisy
Gonçalves, Nilza
Matthews, Helen
Isaacs, Tom
Duffen, Joy
Al-Jawad, Ahmed
Larsen, Frank
Serrano, Artur
Weber, Peter
Thoms, Andrea
Sollinger, Stefan
Graessner, Holm
Maetzler, Walter
Ferreira, Joaquim - Abstract:
- Abstract Background There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson's disease using such devices. However, clinimetric properties and clinical validation vary among the different devices. Methods Given such heterogeneity, we sought to perform a systematic review in order to (i) list, (ii) compare and (iii) classify technological-based devices used to measure motor function in individuals with Parkinson's disease into three groups, namely wearable, non-wearable and hybrid devices. A systematic literature search of the PubMed database resulted in the inclusion of 168 studies. These studies were grouped based on the type of device used. For each device we reviewed availability, use, reliability, validity, and sensitivity to change. The devices were then classified as (i) 'recommended', (ii) 'suggested' or (iii) 'listed' based on the following criteria: (1) used in the assessment of Parkinson's disease (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). Results Seventy-three devices were identified, 22 were wearable, 38 were non-wearable, and 13 were hybrid devices. In accordance with our classification method, 9 devices were 'recommended', 34 devices wereAbstract Background There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson's disease using such devices. However, clinimetric properties and clinical validation vary among the different devices. Methods Given such heterogeneity, we sought to perform a systematic review in order to (i) list, (ii) compare and (iii) classify technological-based devices used to measure motor function in individuals with Parkinson's disease into three groups, namely wearable, non-wearable and hybrid devices. A systematic literature search of the PubMed database resulted in the inclusion of 168 studies. These studies were grouped based on the type of device used. For each device we reviewed availability, use, reliability, validity, and sensitivity to change. The devices were then classified as (i) 'recommended', (ii) 'suggested' or (iii) 'listed' based on the following criteria: (1) used in the assessment of Parkinson's disease (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). Results Seventy-three devices were identified, 22 were wearable, 38 were non-wearable, and 13 were hybrid devices. In accordance with our classification method, 9 devices were 'recommended', 34 devices were 'suggested', and 30 devices were classified as 'listed'. Within the wearable devices group, the Mobility Lab sensors from Ambulatory Parkinson's Disease Monitoring (APDM), Physilog®, StepWatch 3, TriTrac RT3 Triaxial accelerometer, McRoberts DynaPort, and Axivity (AX3) were classified as 'recommended'. Within the non-wearable devices group, the Nintendo Wii Balance Board and GAITRite® gait analysis system were classified as 'recommended'. Within the hybrid devices group only the Kinesia® system was classified as 'recommended'. … (more)
- Is Part Of:
- Journal of neuroengineering and rehabilitation. Volume 13:Issue 1(2016)
- Journal:
- Journal of neuroengineering and rehabilitation
- Issue:
- Volume 13:Issue 1(2016)
- Issue Display:
- Volume 13, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2016-0013-0001-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2016-12
- Subjects:
- Outcomes -- Parkinson's disease -- Quantitative assessment -- Wearable devices -- Monitoring technologies
Nervous system -- Diseases -- Patients -- Rehabilitation -- Periodicals
Nervous system -- Wounds and injuries -- Rehabilitation -- Periodicals
Biomedical engineering
616.8043005 - Journal URLs:
- http://www.jneuroengrehab.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12984-016-0136-7 ↗
- Languages:
- English
- ISSNs:
- 1743-0003
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9888.xml