Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure. Issue 1 (January 2016)
- Main Title:
- Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure
- Authors:
- Silva, T.
Gonçalves, L.
Fonseca, B.
Esteves, S.
Barcellos, D.
Damião, A.
Gonçalves, S. - Abstract:
- Abstract The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT ) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2 O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)A was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)A was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.
- Is Part Of:
- Lasers in medical science. Volume 31:Issue 1(2016)
- Journal:
- Lasers in medical science
- Issue:
- Volume 31:Issue 1(2016)
- Issue Display:
- Volume 31, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2016-0031-0001-0000
- Page Start:
- 49
- Page End:
- 56
- Publication Date:
- 2016-01
- Subjects:
- Adhesion -- Intrapulpal pressure -- Nd:YAG laser -- Temperature
Lasers in medicine -- Periodicals
610.28 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://link.springer.com/journal/10103 ↗
http://www.springer.com/gb/ ↗
http://www.springer.com/gb/ ↗
http://link.springer.de/link/service/journals/10103/index.htm ↗ - DOI:
- 10.1007/s10103-015-1827-1 ↗
- Languages:
- English
- ISSNs:
- 0268-8921
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.680800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9904.xml