Echocardiography-guided percutaneous per-ventricular laser ablation of ventricular septum: in vivo study in a canine model. Issue 4 (May 2016)
- Record Type:
- Journal Article
- Title:
- Echocardiography-guided percutaneous per-ventricular laser ablation of ventricular septum: in vivo study in a canine model. Issue 4 (May 2016)
- Main Title:
- Echocardiography-guided percutaneous per-ventricular laser ablation of ventricular septum: in vivo study in a canine model
- Authors:
- He, Guangbin
Sun, Chao
Zhang, Xiangkong
Zuo, Lei
Qin, Haiying
Zheng, Minjuan
Zhou, Xiaodong
Liu, Liwen - Abstract:
- Abstract Surgical myectomy and ethanol ablation are established intervention strategies for left ventricular outflow obstruction in hypertrophic cardiomyopathy. Safety and efficacy limitations of these interventions call for a minimally invasive, potentially safer, and more efficacious strategy. In this study, we aimed to evaluate the feasibility of echocardiography-guided percutaneous per-ventricular laser ablation of a ventricular septum in a canine model. Six domestic dogs were chosen for the study. A 21G needle was inserted into the right ventricle with its tip reaching the targeted basal to mid-septum, after which laser ablation was performed as follows: 1-W laser for 3 min (180 J) at the basal segment and 5 min (300 J) at middle segment of the septum, respectively. Echocardiography, blood chemistry tests, and pathology examination were performed to assess the results of laser ablation. No death or major complications, i.e., tamponade, pericardial effusion, or ventricular fibrillation, occurred. The laser-ablated areas were well demarcated in the results of the pathological examination. The diameters of the ablated regions were 4.42 ± 0.57 and 5.28 ± 0.83 mm for 3 and 5 min ablation, respectively. Pre-ablation and post-ablation, cardiac enzymes were found to increase significantly while no significant differences were found among M-mode, 2D (LVEF), pulsed-wave (PW) Doppler, and tissue Doppler imaging (TDI) measurements. Contrast echocardiography confirmed the perfusionAbstract Surgical myectomy and ethanol ablation are established intervention strategies for left ventricular outflow obstruction in hypertrophic cardiomyopathy. Safety and efficacy limitations of these interventions call for a minimally invasive, potentially safer, and more efficacious strategy. In this study, we aimed to evaluate the feasibility of echocardiography-guided percutaneous per-ventricular laser ablation of a ventricular septum in a canine model. Six domestic dogs were chosen for the study. A 21G needle was inserted into the right ventricle with its tip reaching the targeted basal to mid-septum, after which laser ablation was performed as follows: 1-W laser for 3 min (180 J) at the basal segment and 5 min (300 J) at middle segment of the septum, respectively. Echocardiography, blood chemistry tests, and pathology examination were performed to assess the results of laser ablation. No death or major complications, i.e., tamponade, pericardial effusion, or ventricular fibrillation, occurred. The laser-ablated areas were well demarcated in the results of the pathological examination. The diameters of the ablated regions were 4.42 ± 0.57 and 5.28 ± 0.83 mm for 3 and 5 min ablation, respectively. Pre-ablation and post-ablation, cardiac enzymes were found to increase significantly while no significant differences were found among M-mode, 2D (LVEF), pulsed-wave (PW) Doppler, and tissue Doppler imaging (TDI) measurements. Contrast echocardiography confirmed the perfusion defects in the ablated regions. Microscopically, the ablated myocardium showed coagulative changes and a sparse distribution of disappearing nuclei and an increase in eosinophil number were observed. Our study suggests that percutaneous and per-ventricular laser ablation of the septum is feasible, potentially safe and efficacious, and warrants further investigation and validation. … (more)
- Is Part Of:
- Lasers in medical science. Volume 31:Issue 4(2016)
- Journal:
- Lasers in medical science
- Issue:
- Volume 31:Issue 4(2016)
- Issue Display:
- Volume 31, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2016-0031-0004-0000
- Page Start:
- 645
- Page End:
- 651
- Publication Date:
- 2016-05
- Subjects:
- Laser ablation -- Septum -- Echocardiography -- Percutaneous -- Per-ventricular -- Intervention
Lasers in medicine -- Periodicals
610.28 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://link.springer.com/journal/10103 ↗
http://www.springer.com/gb/ ↗
http://www.springer.com/gb/ ↗
http://link.springer.de/link/service/journals/10103/index.htm ↗ - DOI:
- 10.1007/s10103-016-1881-3 ↗
- Languages:
- English
- ISSNs:
- 0268-8921
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.680800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9894.xml