Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness. Issue 1 (December 2016)
- Main Title:
- Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness
- Authors:
- Whitford, Charles
Joda, Akram
Jones, Steve
Bao, Fangjun
Rama, Paolo
Elsheikh, Ahmed - Abstract:
- Abstract Background The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. Methods A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye's outer tunic. Results The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera's stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in theAbstract Background The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. Methods A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye's outer tunic. Results The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera's stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone. Further, for both the sclera and cornea, the load–displacement behaviour did not vary significantly between loading cycles. Conclusions The first methodology capable of mechanically testing intact eye globes, with applied loads and boundary conditions that closely represent in vivo conditions is introduced. The method enables determination of the regional variation in mechanical behaviour across the ocular surface. … (more)
- Is Part Of:
- Eye and vision. Volume 3:Issue 1(2016)
- Journal:
- Eye and vision
- Issue:
- Volume 3:Issue 1(2016)
- Issue Display:
- Volume 3, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2016-0003-0001-0000
- Page Start:
- 1
- Page End:
- 12
- Publication Date:
- 2016-12
- Subjects:
- Ocular biomechanics -- Experimental testing -- Digital image correlation
Ophthalmology -- Periodicals
Vision -- Periodicals
Optometry -- Periodicals
617.7 - Journal URLs:
- http://www.eandv.org/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s40662-016-0052-8 ↗
- Languages:
- English
- ISSNs:
- 2326-0254
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9870.xml