Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?. Issue 1 (December 2015)
- Main Title:
- Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?
- Authors:
- Dahl, Michael
Hayes, Chris
Steen Rasmussen, Bodil
Larsson, Anders
Secher, Niels - Abstract:
- Abstract Background Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac output (CO). This study tested that hypothesis in healthy volunteers exposed to central hypovolemia by head-up tilt. Methods Thirteen healthy volunteers were exposed to central hypovolemia by 45° head-up tilt while breathing through a facemask with 7.5 cmH2 O inspiratory and/or expiratory resistors. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation (SPV), pulse pressure variation and stroke volume variation . Pulse contour analysis determined stroke volume (SV) and CO and we evaluated whether APV could detect a 10 % decrease in CO. Results During head-up tilt SV decreased form 91 (±46) to 55 (±24) mL (mean ± SD) and CO from 5.8 (±2.9) to 4.0 (±1.8) L/min (p < 0.05), while heart rate increased (65 (±11) to 75 (±13) bpm;P < 0.05). Systolic pressure decreased from 127 (±14) to 121 (±13) mmHg during head-up tilt, while SPV tended to increase (from 21 (±15)% to 30 (±13)%). Yet during head-up tilt, a SPV ≥ 37 % predicted a decrease in CO ≥ 10 % with a sensitivity and specificity of 78 % and 100 %, respectively. Conclusion In spontaneously breathing healthy volunteers combined inspiratory and expiratory resistors enhance SPVAbstract Background Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac output (CO). This study tested that hypothesis in healthy volunteers exposed to central hypovolemia by head-up tilt. Methods Thirteen healthy volunteers were exposed to central hypovolemia by 45° head-up tilt while breathing through a facemask with 7.5 cmH2 O inspiratory and/or expiratory resistors. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation (SPV), pulse pressure variation and stroke volume variation . Pulse contour analysis determined stroke volume (SV) and CO and we evaluated whether APV could detect a 10 % decrease in CO. Results During head-up tilt SV decreased form 91 (±46) to 55 (±24) mL (mean ± SD) and CO from 5.8 (±2.9) to 4.0 (±1.8) L/min (p < 0.05), while heart rate increased (65 (±11) to 75 (±13) bpm;P < 0.05). Systolic pressure decreased from 127 (±14) to 121 (±13) mmHg during head-up tilt, while SPV tended to increase (from 21 (±15)% to 30 (±13)%). Yet during head-up tilt, a SPV ≥ 37 % predicted a decrease in CO ≥ 10 % with a sensitivity and specificity of 78 % and 100 %, respectively. Conclusion In spontaneously breathing healthy volunteers combined inspiratory and expiratory resistors enhance SPV during head-up tilted induced central hypovolemia and allow identifying a 10 % reduction in CO. Applying inspiratory and expiratory resistors might detect a fluid deficit in spontaneously breathing patients. Trial registration ClinicalTrials.gov numberNCT02549482 Registered September 10th 2015. … (more)
- Is Part Of:
- BMC anesthesiology. Volume 16:Issue 1(2016)
- Journal:
- BMC anesthesiology
- Issue:
- Volume 16:Issue 1(2016)
- Issue Display:
- Volume 16, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2016-0016-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Fluid responsiveness -- Spontaneous breathing -- Head-up tilt -- Pulse pressure variation -- Stroke volume variation -- Systolic pressure variation
Anesthetics -- Periodicals
Anesthesia -- Periodicals
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://www.biomedcentral.com/bmcanesthesiol/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=11 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12871-016-0224-z ↗
- Languages:
- English
- ISSNs:
- 1471-2253
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 9872.xml