Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study. Issue 1 (December 2015)
- Main Title:
- Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study
- Authors:
- Kang, Hyun
Kim, Dong
Jung, Yong
Baek, Chong
Park, Yong
Oh, Jong
Kim, Won
Choi, Geun - Abstract:
- Abstract Background The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters. Methods Ninety adult patients were assigned equally randomized to either Group W or Group R. Anesthesia was induced using propofol, fentanyl, and rocuronium. In Group W, the SLIPA was warmed to 37 ° C before insertion, whereas in Group R, it was inserted at room temperature. The insertion time, oropharyngeal leak pressure, postoperative throat pain, blood staining, regurgitation, number of attempts at insertion, and difficulty of insertion were compared between the two groups. Results The insertion time was shorter in Group W than in Group R (3.60 [3.15–4.06] s vs. 6.00 [4.45–7.50] s;P < 0.001). Oropharyngeal leak pressure from the time of insertion until 3 min after insertion was significantly higher in Group W than in Group R (P < 0.05). Postoperative throat pain, measured using the visual analog scale, was lower in Group W than in Group R (0.00 [0.00–2.50] vs. 2.00 [0.00–4.50];P = 0.006). The difficulty of insertion was lower in Group W than in Group R (P < 0.004). There were no significant differences in terms of blood staining, regurgitation, and number of attempts. Conclusions Pre-warming the SLIPA to body temperature has significant benefits compared to maintaining the deviceAbstract Background The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters. Methods Ninety adult patients were assigned equally randomized to either Group W or Group R. Anesthesia was induced using propofol, fentanyl, and rocuronium. In Group W, the SLIPA was warmed to 37 ° C before insertion, whereas in Group R, it was inserted at room temperature. The insertion time, oropharyngeal leak pressure, postoperative throat pain, blood staining, regurgitation, number of attempts at insertion, and difficulty of insertion were compared between the two groups. Results The insertion time was shorter in Group W than in Group R (3.60 [3.15–4.06] s vs. 6.00 [4.45–7.50] s;P < 0.001). Oropharyngeal leak pressure from the time of insertion until 3 min after insertion was significantly higher in Group W than in Group R (P < 0.05). Postoperative throat pain, measured using the visual analog scale, was lower in Group W than in Group R (0.00 [0.00–2.50] vs. 2.00 [0.00–4.50];P = 0.006). The difficulty of insertion was lower in Group W than in Group R (P < 0.004). There were no significant differences in terms of blood staining, regurgitation, and number of attempts. Conclusions Pre-warming the SLIPA to body temperature has significant benefits compared to maintaining the device at room temperature. Specifically, insertion was easier, both insertion and fitting to the laryngeal structure could be performed more quickly, and the incidence of sore throat was reduced. Trial registration Clinical Research Information IdentifierNCT01209000 … (more)
- Is Part Of:
- BMC anesthesiology. Volume 15:Issue 1(2015)
- Journal:
- BMC anesthesiology
- Issue:
- Volume 15:Issue 1(2015)
- Issue Display:
- Volume 15, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2015-0015-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2015-12
- Subjects:
- Pre-warming -- SLIPA -- Oropharyngeal leak pressure -- Supraglottic airway devices
Anesthetics -- Periodicals
Anesthesia -- Periodicals
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://www.biomedcentral.com/bmcanesthesiol/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=11 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12871-015-0151-4 ↗
- Languages:
- English
- ISSNs:
- 1471-2253
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 9882.xml