Can local staff reliably assess their own programs? A confirmatory test-retest study of Lot Quality Assurance Sampling data collectors in Uganda. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Can local staff reliably assess their own programs? A confirmatory test-retest study of Lot Quality Assurance Sampling data collectors in Uganda. Issue 1 (December 2016)
- Main Title:
- Can local staff reliably assess their own programs? A confirmatory test-retest study of Lot Quality Assurance Sampling data collectors in Uganda
- Authors:
- Beckworth, Colin
Anguyo, Robert
Kyakulaga, Francis
Lwanga, Stephen
Valadez, Joseph - Abstract:
- Abstract Background Data collection techniques that routinely provide health system information at the local level are in demand and needed. LQAS is intended for use by local health teams to collect data at the district and sub-district levels. Our question is whether local health staff produce biased results as they are responsible for implementing the programs they also assess. Methods This test-retest study replicates on a larger scale an earlier LQAS reliability assessment in Uganda. We conducted in two districts an LQAS survey using 15 local health staff as data collectors. A week later, the data collectors swapped districts, where they acted as disinterested non-local data collectors, repeating the LQAS survey with the same respondents. We analysed the resulting two data sets for agreement using Cohens' Kappa. Results The average Kappa score for the knowledge indicators was k = 0.43 (SD = 0.16) and for practice indicators k = 0.63 (SD = 0.17). These scores show moderate agreement for knowledge indicators and substantial agreement for practice indicators. Analyses confirm that respondents were more knowledgeable on retest; no evidence of bias was found for practice indicators. Conclusion The findings of this study are remarkably similar to those produced in the first reliability study. There is no evidence that using local healthcare staff to collect LQAS data biases data collection in an LQAS study. The bias observed in the knowledge indicators was most likely due to aAbstract Background Data collection techniques that routinely provide health system information at the local level are in demand and needed. LQAS is intended for use by local health teams to collect data at the district and sub-district levels. Our question is whether local health staff produce biased results as they are responsible for implementing the programs they also assess. Methods This test-retest study replicates on a larger scale an earlier LQAS reliability assessment in Uganda. We conducted in two districts an LQAS survey using 15 local health staff as data collectors. A week later, the data collectors swapped districts, where they acted as disinterested non-local data collectors, repeating the LQAS survey with the same respondents. We analysed the resulting two data sets for agreement using Cohens' Kappa. Results The average Kappa score for the knowledge indicators was k = 0.43 (SD = 0.16) and for practice indicators k = 0.63 (SD = 0.17). These scores show moderate agreement for knowledge indicators and substantial agreement for practice indicators. Analyses confirm that respondents were more knowledgeable on retest; no evidence of bias was found for practice indicators. Conclusion The findings of this study are remarkably similar to those produced in the first reliability study. There is no evidence that using local healthcare staff to collect LQAS data biases data collection in an LQAS study. The bias observed in the knowledge indicators was most likely due to a 'practice effect', whereby respondents increased their knowledge as a result of completing the first survey; no corresponding effect was seen in the practice indicators. … (more)
- Is Part Of:
- BMC health services research. Volume 16:Issue 1(2016)
- Journal:
- BMC health services research
- Issue:
- Volume 16:Issue 1(2016)
- Issue Display:
- Volume 16, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2016-0016-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2016-12
- Subjects:
- LQAS -- Lot Quality Assurance Sampling -- Test retest -- Cohen's kappa -- Bias
Public health -- Research -- Periodicals
Medical care -- Research -- Periodicals
362.1072 - Journal URLs:
- http://www.biomedcentral.com/bmchealthservres/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=34 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12913-016-1655-4 ↗
- Languages:
- English
- ISSNs:
- 1472-6963
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9863.xml