Li, Bin - Abstract:
- Abstract Background Carbapenem-resistantEnterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. Methods A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. Results PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably,Abstract Background Carbapenem-resistantEnterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. Methods A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. Results PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, oneKlebsiella pneumoniae isolate produced both IMP-4 and NDM-1. OneKlebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. Conclusions The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of CRE, whereas additional tests are required for the Pheonix 100 system. Our study provides a useful guideline for using automated identification systems for CRE identification. … (more)
- Is Part Of:
- Annals of clinical microbiology and antimicrobials. Volume 15:Issue 1(2016)
- Journal:
- Annals of clinical microbiology and antimicrobials
- Issue:
- Volume 15:Issue 1(2016)
- Issue Display:
- Volume 15, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2016-0015-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2016-12
- Subjects:
- Carbapenem-resistant Enterobacteriaceae -- Automated identification systems -- PCR
Medical microbiology -- Periodicals
Anti-infective agents -- Periodicals
616.9041 - Journal URLs:
- http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=121 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12941-016-0154-0 ↗
- Languages:
- English
- ISSNs:
- 1476-0711
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9846.xml