Compensation of volatile-distributed current due to variance of the unknown contact impedance in an electrical impedance tomography sensor. (14th February 2019)
- Record Type:
- Journal Article
- Title:
- Compensation of volatile-distributed current due to variance of the unknown contact impedance in an electrical impedance tomography sensor. (14th February 2019)
- Main Title:
- Compensation of volatile-distributed current due to variance of the unknown contact impedance in an electrical impedance tomography sensor
- Authors:
- Baidillah, Marlin Ramadhan
Kawashima, Daisuke
Takei, Masahiro - Abstract:
- Abstract: A weighted parameter vector χ norm based on extracellular fluid resistance in the Cole impedance model is hereby proposed in order to compensate for the volatile-distributed current. The volatile-distributed current due to variance in the unknown contact impedance in an electrical impedance tomography (EIT) sensor distorts the ideality of the frequency-dependent behavior of the object of interest, leading to inaccuracy in the reconstructed images. The sources of variance in the unknown contact impedance include the use of electrodes with inconsistent impedance values, electrochemical reaction or the improper attachment of electrodes to the object of interest. χ norm represents the current pathway lengths at zero frequency which reflects the volatile-distributed current, and it is used to determine the source of the measured impedance. The source of the unknown contact impedance can be the background object in the normal physiological condition, an inclusion object in an abnormal physiological condition or systematic error. The new reconstruction methods are derived from the frequency-difference EIT (fd-EIT) and the weighted-frequency-difference EIT (wfd-EIT) using χ norm . The new reconstruction methods are frequency-difference electrical impedance spectro-tomography (fd-EIST) and weighted-frequency-difference electrical impedance spectro-tomography (wfd-EIST). The performance of fd-EIST and wfd-EIST was evaluated by experimental and simulation studies usingAbstract: A weighted parameter vector χ norm based on extracellular fluid resistance in the Cole impedance model is hereby proposed in order to compensate for the volatile-distributed current. The volatile-distributed current due to variance in the unknown contact impedance in an electrical impedance tomography (EIT) sensor distorts the ideality of the frequency-dependent behavior of the object of interest, leading to inaccuracy in the reconstructed images. The sources of variance in the unknown contact impedance include the use of electrodes with inconsistent impedance values, electrochemical reaction or the improper attachment of electrodes to the object of interest. χ norm represents the current pathway lengths at zero frequency which reflects the volatile-distributed current, and it is used to determine the source of the measured impedance. The source of the unknown contact impedance can be the background object in the normal physiological condition, an inclusion object in an abnormal physiological condition or systematic error. The new reconstruction methods are derived from the frequency-difference EIT (fd-EIT) and the weighted-frequency-difference EIT (wfd-EIT) using χ norm . The new reconstruction methods are frequency-difference electrical impedance spectro-tomography (fd-EIST) and weighted-frequency-difference electrical impedance spectro-tomography (wfd-EIST). The performance of fd-EIST and wfd-EIST was evaluated by experimental and simulation studies using biomaterials with frequency measurements from f = 500 Hz to f = 100 kHz and the results were compared with those from fd-EIT and wfd-EIT. The results showed that the use of χ norm reduces the root mean square error, position error, ringing and shape deformation. It also increases the ideality of the frequency-dependent behavior, either for the inclusions or the background objects at different frequencies. … (more)
- Is Part Of:
- Measurement science & technology. Volume 30:Number 3(2019:Mar.)
- Journal:
- Measurement science & technology
- Issue:
- Volume 30:Number 3(2019:Mar.)
- Issue Display:
- Volume 30, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2019-0030-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02-14
- Subjects:
- electrical impedance spectro-tomography -- Cole impedance model -- unknown contact impedance variance -- volatile-distributed current
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/aafb22 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9846.xml