Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. Issue 4 (22nd January 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. Issue 4 (22nd January 2019)
- Main Title:
- Accuracy of Fractional Flow Reserve Derived From Coronary Angiography
- Authors:
- Fearon, William F.
Achenbach, Stephan
Engstrom, Thomas
Assali, Abid
Shlofmitz, Richard
Jeremias, Allen
Fournier, Stephane
Kirtane, Ajay J.
Kornowski, Ran
Greenberg, Gabriel
Jubeh, Rami
Kolansky, Daniel M.
McAndrew, Thomas
Dressler, Ovidiu
Maehara, Akiko
Matsumura, Mitsuaki
Leon, Martin B.
De Bruyne, Bernard - Abstract:
- Abstract : Background: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFRangio ) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFRangio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFRangio . Methods: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFRangio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFRangio for predicting pressure wire–derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. Results: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR⩽0.80. The per-vessel sensitivity and specificity were 94% (95%Abstract : Background: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFRangio ) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFRangio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFRangio . Methods: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFRangio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFRangio for predicting pressure wire–derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. Results: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR⩽0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFRangio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFRangio values correlated well with FFR measurements ( r =0.80, P <0.001) and the Bland–Altman 95% confidence limits were between −0.14 and 0.12. The device success rate for FFRangio was 99%. Conclusions: FFRangio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire–derived FFR. FFRangio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes. Clinical Trial Registration: URL:https://www.clinicaltrials.gov . Unique Identifier: NCT03226262. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 139:Issue 4(2019)
- Journal:
- Circulation
- Issue:
- Volume 139:Issue 4(2019)
- Issue Display:
- Volume 139, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 139
- Issue:
- 4
- Issue Sort Value:
- 2019-0139-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01-22
- Subjects:
- coronary artery disease -- coronary circulation -- fractional flow reserve, myocardial
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.118.037350 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9841.xml