Technical considerations for generating somatosensation via cortical stimulation in a closed-loop sensory/motor brain-computer interface system in humans. (May 2019)
- Record Type:
- Journal Article
- Title:
- Technical considerations for generating somatosensation via cortical stimulation in a closed-loop sensory/motor brain-computer interface system in humans. (May 2019)
- Main Title:
- Technical considerations for generating somatosensation via cortical stimulation in a closed-loop sensory/motor brain-computer interface system in humans
- Authors:
- Kramer, Daniel R.
Kellis, Spencer
Barbaro, Michael
Salas, Michelle Armenta
Nune, George
Liu, Charles Y.
Andersen, Richard A.
Lee, Brian - Abstract:
- Highlights: Comparison of electrode array modalities for somatosensory BCI in humans. Microelectrode array has good resolution, but poor coverage and high redundancy. 3 cm electrocorticography spacing has ideal balance of coverage, and specificity. Abstract: Somatosensory feedback is the next step in brain computer interface (BCI). Here, we compare three cortical stimulating array modalities for generating somatosensory percepts in BCI. We compared human subjects with either a 64-channel "mini"-electrocorticography grid (mECoG; 1.2-mm diameter exposed contacts with 3-mm spacing, N = 1) over the hand area of primary somatosensory cortex (S1), or a standard grid (sECoG; 1.5-mm diameter exposed contacts with 1-cm spacing, N = 1), to generate artificial somatosensation through direct electrical cortical stimulation. Finally, we reference data in the literature from a patient implanted with microelectrode arrays (MEA) placed in the S1 hand area. We compare stimulation results to assess coverage and specificity of the artificial percepts in the hand. Using the mECoG array, hand mapping revealed coverage of 41.7% of the hand area versus 100% for the sECoG array, and 18.8% for the MEA. On average, stimulation of a single electrode corresponded to sensation reported in 4.42 boxes (range 1–11 boxes) for the mECoG array, 19.11 boxes (range 4–48 boxes) for the sECoG grid, and 2.3 boxes (range 1–5 boxes) for the MEA. Sensation in any box, on average, corresponded to stimulation from 2.65Highlights: Comparison of electrode array modalities for somatosensory BCI in humans. Microelectrode array has good resolution, but poor coverage and high redundancy. 3 cm electrocorticography spacing has ideal balance of coverage, and specificity. Abstract: Somatosensory feedback is the next step in brain computer interface (BCI). Here, we compare three cortical stimulating array modalities for generating somatosensory percepts in BCI. We compared human subjects with either a 64-channel "mini"-electrocorticography grid (mECoG; 1.2-mm diameter exposed contacts with 3-mm spacing, N = 1) over the hand area of primary somatosensory cortex (S1), or a standard grid (sECoG; 1.5-mm diameter exposed contacts with 1-cm spacing, N = 1), to generate artificial somatosensation through direct electrical cortical stimulation. Finally, we reference data in the literature from a patient implanted with microelectrode arrays (MEA) placed in the S1 hand area. We compare stimulation results to assess coverage and specificity of the artificial percepts in the hand. Using the mECoG array, hand mapping revealed coverage of 41.7% of the hand area versus 100% for the sECoG array, and 18.8% for the MEA. On average, stimulation of a single electrode corresponded to sensation reported in 4.42 boxes (range 1–11 boxes) for the mECoG array, 19.11 boxes (range 4–48 boxes) for the sECoG grid, and 2.3 boxes (range 1–5 boxes) for the MEA. Sensation in any box, on average, corresponded to stimulation from 2.65 electrodes (range 1–5 electrodes) for the mECoG grid, 3.58 electrodes for the sECoG grid (range 2–4 electrodes), and 11.22 electrodes (range 2–17 electrodes) for the MEA. Based on these findings, we conclude that mECoG grids provide an excellent balance between spatial cortical coverage of the hand area of S1 and high-density resolution. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 63(2019)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 63(2019)
- Issue Display:
- Volume 63, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 63
- Issue:
- 2019
- Issue Sort Value:
- 2019-0063-2019-0000
- Page Start:
- 116
- Page End:
- 121
- Publication Date:
- 2019-05
- Subjects:
- Somatosensory -- Brain computer interface (BCI) -- Brain machine interface (BMI) -- Electrocorticography -- Cortical stimulation
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2019.01.027 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9828.xml