ATP bioluminescence values are significantly different depending upon material surface properties of the sampling location in hospitals. (December 2015)
- Record Type:
- Journal Article
- Title:
- ATP bioluminescence values are significantly different depending upon material surface properties of the sampling location in hospitals. (December 2015)
- Main Title:
- ATP bioluminescence values are significantly different depending upon material surface properties of the sampling location in hospitals
- Authors:
- Shimoda, Tomoko
Yano, Rika
Nakamura, Shinji
Yoshida, Mitsutaka
Matsuo, Junji
Yoshimura, Sadako
Yamaguchi, Hiroyuki - Abstract:
- Abstract Background Our previous study into assessing hospital cleanliness in Japan by two common methods, ATP bioluminescence and the stamp agar method, revealed considerable variability in the data of both methods (BMC Research Notes, 7: 121, 2014). To investigate the reason(s) for the variability, we reanalyzed the data (n = 752) from the point of view of the material surface properties of sampling sites. Methods Data obtained from surfaces with unknown properties and different purposes such as floor were omitted, and the remaining data (n = 488) were used for this study. The material surface properties on sampling sites were divided into six categories: melamine coated (n = 216), vinyl chloride (n = 16), stainless steel (n = 144), wood (n = 63), and acrylonitrile-butadiene styrene resin coated (n = 48). The data between individual material properties were compared. Results The ATP values of high-touch places were significantly different depending on the type of surface, but no significant difference in stamp values between material properties was seen, indicating that in contrast to stamp values, ATP-accumulation more depends on the physical properties of the material surface such as electronic charges or roughness. To confirm this, we assessed a degree of roughness on vinyl chloride material surface (disutilized floor samples actually used for each of the hospitals) by observation with scanning electron microscope (SEM). As a result, SEM observation similarlyAbstract Background Our previous study into assessing hospital cleanliness in Japan by two common methods, ATP bioluminescence and the stamp agar method, revealed considerable variability in the data of both methods (BMC Research Notes, 7: 121, 2014). To investigate the reason(s) for the variability, we reanalyzed the data (n = 752) from the point of view of the material surface properties of sampling sites. Methods Data obtained from surfaces with unknown properties and different purposes such as floor were omitted, and the remaining data (n = 488) were used for this study. The material surface properties on sampling sites were divided into six categories: melamine coated (n = 216), vinyl chloride (n = 16), stainless steel (n = 144), wood (n = 63), and acrylonitrile-butadiene styrene resin coated (n = 48). The data between individual material properties were compared. Results The ATP values of high-touch places were significantly different depending on the type of surface, but no significant difference in stamp values between material properties was seen, indicating that in contrast to stamp values, ATP-accumulation more depends on the physical properties of the material surface such as electronic charges or roughness. To confirm this, we assessed a degree of roughness on vinyl chloride material surface (disutilized floor samples actually used for each of the hospitals) by observation with scanning electron microscope (SEM). As a result, SEM observation similarly revealed considerable roughness on the materials, which may allow microbes to contaminate the materials without noticing it. Conclusion Material properties must be considered when evaluating hospital cleanliness with ATP values, and provide a strong warning into evaluating hospital cleanliness. … (more)
- Is Part Of:
- BMC research notes. Volume 8:Number 1(2015)
- Journal:
- BMC research notes
- Issue:
- Volume 8:Number 1(2015)
- Issue Display:
- Volume 8, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2015-0008-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Material properties -- Hospital cleanliness -- ATP bioluminescence -- Stamp agar -- Culture -- Scanning electron microscopy
Medicine -- Periodicals
Biology -- Periodicals
610.5 - Journal URLs:
- http://www.biomedcentral.com/bmcresnotes ↗
http://www.biomedcentral.com/bmcresnotes/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13104-015-1757-9 ↗
- Languages:
- English
- ISSNs:
- 1756-0500
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9818.xml