Single-particle ICP-MS with online microdroplet calibration: toward matrix independent nanoparticle sizing. Issue 4 (15th January 2019)
- Record Type:
- Journal Article
- Title:
- Single-particle ICP-MS with online microdroplet calibration: toward matrix independent nanoparticle sizing. Issue 4 (15th January 2019)
- Main Title:
- Single-particle ICP-MS with online microdroplet calibration: toward matrix independent nanoparticle sizing
- Authors:
- Hendriks, Lyndsey
Ramkorun-Schmidt, Benita
Gundlach-Graham, Alexander
Koch, Julian
Grass, Robert N.
Jakubowski, Norbert
Günther, Detlef - Abstract:
- Abstract : Microdroplets with known concentrations of element standards are introduced concomitant with NP-containing solutions into the ICP to provide online matrix-matched calibration of analyte NPs for single-particle-ICP-TOFMS. Abstract : Single-particle inductively coupled plasma mass spectrometry ( sp -ICP-MS) has become an effective tool for the detection and quantification of inorganic nanoparticles (NPs). While sizing of NPs suspended in water is relatively straightforward by sp -ICP-MS, accurate mass quantification of NPs in complex media, such as consumer products and natural systems still remains a challenge. When NPs are suspended in a complex medium, the matrix may affect the analyte sensitivity and lead to inaccurate NP sizing. Here, we investigate the use of an online microdroplet calibration system to size NPs in a single step. In this setup, microdroplets—which are used as the calibrant to determine elemental sensitivities—and nebulized NP-containing solutions are introduced concurrently into the ICP via a dual-inlet sample introduction system. Because calibrant microdroplets and analyte NPs experience the same plasma conditions, both the microdroplets and the NPs are subjected to the same matrix-related signal enhancement or suppression. In this way, the microdroplet calibration standards are automatically matrix matched with the NP-containing solution. The online microdroplet calibration system is combined with an ICP-TOFMS instrument for simultaneousAbstract : Microdroplets with known concentrations of element standards are introduced concomitant with NP-containing solutions into the ICP to provide online matrix-matched calibration of analyte NPs for single-particle-ICP-TOFMS. Abstract : Single-particle inductively coupled plasma mass spectrometry ( sp -ICP-MS) has become an effective tool for the detection and quantification of inorganic nanoparticles (NPs). While sizing of NPs suspended in water is relatively straightforward by sp -ICP-MS, accurate mass quantification of NPs in complex media, such as consumer products and natural systems still remains a challenge. When NPs are suspended in a complex medium, the matrix may affect the analyte sensitivity and lead to inaccurate NP sizing. Here, we investigate the use of an online microdroplet calibration system to size NPs in a single step. In this setup, microdroplets—which are used as the calibrant to determine elemental sensitivities—and nebulized NP-containing solutions are introduced concurrently into the ICP via a dual-inlet sample introduction system. Because calibrant microdroplets and analyte NPs experience the same plasma conditions, both the microdroplets and the NPs are subjected to the same matrix-related signal enhancement or suppression. In this way, the microdroplet calibration standards are automatically matrix matched with the NP-containing solution. The online microdroplet calibration system is combined with an ICP-TOFMS instrument for simultaneous measurement of multiple elements in microdroplets and NPs. We investigate the ability of online microdroplet calibration to compensate for matrix effects through a series of experiments, in which Ag and Au NPs are measured with variable plasma-sampling positions, varying concentrations of HCl and HNO3, varying concentrations of single element solutions, and high concentrations of a salt matrix, i.e. phosphate buffered saline (PBS). Through these experiments, we demonstrate that the online microdroplet calibration strategy provides a matrix-independent mass quantification of analyte NPs in the presence of several established types of matrix effects, including acid effects, space-charge effects, and ionisation suppression. In results presented here, we focus on the size determination of the NPs. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 34:Issue 4(2019)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 34:Issue 4(2019)
- Issue Display:
- Volume 34, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2019-0034-0004-0000
- Page Start:
- 716
- Page End:
- 728
- Publication Date:
- 2019-01-15
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ja00397a ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9812.xml