Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study. Issue 1 (December 2015)
- Main Title:
- Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study
- Authors:
- Arsenijevic, Petar
Milosevic, Marko
Zivanovic, Aleksandar
Milicic, Biljana
Jeremic, Branislav
Filipovic, Nenad
Protrka, Zoran
Todorovic, Petar
Arsenijevic, Slobodan - Abstract:
- Abstract Background Hydraulic dilatation is a novel method of cervical dilatation that is based on continuous controllable dilatation (CCBD) by the pumping of fluid into the balloon extension of the system. The main advantage of this procedure is that it allows control of and insight into the process of cervical dilatation. Methods For the purposes of our research, we created a new and upgraded system for CCBD which consists of a programmed hydrostatic pump connected to a balloon extension. With regard to our aim to precisely measure and determine the location of the cervical resistance, we placed two pressure-measuring films, one on the top and one on the bottom of the balloon extension. This study included 42 patients in whom cervical resistance was measured before suction curettage. Results Cervical dilatation and measurement of cervical resistance were successful in all patients. The analysis of the pressure-measuring films showed that the points of highest resistance were located in the zone of the internal cervical os and that these values were much higher than those in the zone of the external cervical os (0.402 versus 0.264 MPa at the upper pressure-sensitive film; 0.387 versus 0.243 MPa at the lower pressure-sensitive film). This study also showed that an increase in cervical resistance in the zone of the internal cervical os was followed by an increase in cervical resistance in the zone of the external cervical os. Conclusions During CCBD, the internal cervical osAbstract Background Hydraulic dilatation is a novel method of cervical dilatation that is based on continuous controllable dilatation (CCBD) by the pumping of fluid into the balloon extension of the system. The main advantage of this procedure is that it allows control of and insight into the process of cervical dilatation. Methods For the purposes of our research, we created a new and upgraded system for CCBD which consists of a programmed hydrostatic pump connected to a balloon extension. With regard to our aim to precisely measure and determine the location of the cervical resistance, we placed two pressure-measuring films, one on the top and one on the bottom of the balloon extension. This study included 42 patients in whom cervical resistance was measured before suction curettage. Results Cervical dilatation and measurement of cervical resistance were successful in all patients. The analysis of the pressure-measuring films showed that the points of highest resistance were located in the zone of the internal cervical os and that these values were much higher than those in the zone of the external cervical os (0.402 versus 0.264 MPa at the upper pressure-sensitive film; 0.387 versus 0.243 MPa at the lower pressure-sensitive film). This study also showed that an increase in cervical resistance in the zone of the internal cervical os was followed by an increase in cervical resistance in the zone of the external cervical os. Conclusions During CCBD, the internal cervical os is the centre of cervical resistance, and the values do not decline with the number of miscarriages or the number of previous births. Trial registration number ISRCTN Registry identifier:ISRCTN30949871 . Date of registration: 13 May 2015. … (more)
- Is Part Of:
- Trials. Volume 16:Issue 1(2015)
- Journal:
- Trials
- Issue:
- Volume 16:Issue 1(2015)
- Issue Display:
- Volume 16, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2015-0016-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Cervical resistance -- Continuous controllable balloon dilatation -- Measurement and analysis
Group-randomized trials -- Periodicals
Randomized Controlled Trials -- Periodicals
615.0727 - Journal URLs:
- http://www.pubmedcentral.gov/tocrender.fcgi?iid=11709 ↗
http://www.trialsjournal.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13063-015-1003-8 ↗
- Languages:
- English
- ISSNs:
- 1745-6215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9798.xml