Monocytes in Icelandic horses: comparison between automatic gating by the ADVIA 2120i, a manual gating method and microscopic differentiation. (November 2015)
- Record Type:
- Journal Article
- Title:
- Monocytes in Icelandic horses: comparison between automatic gating by the ADVIA 2120i, a manual gating method and microscopic differentiation. (November 2015)
- Main Title:
- Monocytes in Icelandic horses: comparison between automatic gating by the ADVIA 2120i, a manual gating method and microscopic differentiation
- Authors:
- Leidinger, E.
Prechtl, G.
Figl, J.
Leidinger, J. - Abstract:
- Abstract Inspection of the ADVIA 2120i PEROX cytograms from healthy Icelandic horses revealed a mismatch of the automatic gating (A) for monocytes, resulting in a lower percentage. The raw data of 40 Icelandic horses were transformed to FCS files. Data were imported to WinMDI 2.9 (Purdue Cytometry Laboratories) and gated manually (M). In addition, a manual 200-cell differential (D) was performed. ANOVA was used to test for significant differences. RefVal 2.1 (Toulouse Veterinary School) was used to calculate the reference values by different methods. Significance level was set atP < 0.05. Monocytes were significantly higher by M compared to A and D, neutrophils were significantly lower for A compared to M, but not for A compared to D. Data were used to calculate the RI as follows: neutrophils (A) 37.7–65.6 % (1.7–4.6 × 109 /L); neutrophils (M): 33.8–61.8 % (1.6–4.3 × 109 /L); lymphocytes (A): 26.0–52.7 % (1.1–4.6 × 109 /L), lymphocytes (M): 28.1–55.5 % (1.2–4.0 × 109 /L); monocytes (A): 1.5–4.6 % (0.1–0.4 × 109 /L); monocytes (M): 3.4–6.9 % (0.2–0.5 × 109 /L). The ADVIA 2120i built-in export function and the use of WinMDI allow a very precise recalculation of cell populations. Icelandic horses reportedly have the lowest monocyte number of all horse breeds. This may be possibly caused by higher MPO activity and/or an inaccuracy of the algorithm used.
- Is Part Of:
- Comparative clinical pathology. Volume 24:Number 6(2015)
- Journal:
- Comparative clinical pathology
- Issue:
- Volume 24:Number 6(2015)
- Issue Display:
- Volume 24, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 6
- Issue Sort Value:
- 2015-0024-0006-0000
- Page Start:
- 1353
- Page End:
- 1359
- Publication Date:
- 2015-11
- Subjects:
- Horse breed -- Blood smear -- Myeloperoxidase -- Cytometry software -- Reference interval
Diagnosis, Laboratory -- Periodicals
Pathology, Comparative -- Periodicals
616.07 - Journal URLs:
- http://www.metapress.com/link.asp?id=102819 ↗
http://www.springerlink.com/content/1618-5641/ ↗
http://www.springerlink.com/link.asp?id=102819 ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s00580-015-2080-5 ↗
- Languages:
- English
- ISSNs:
- 1618-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3363.752705
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: