Factors affecting the concordance of radiologic and pathologic tumor size in breast carcinoma. (February 2019)
- Record Type:
- Journal Article
- Title:
- Factors affecting the concordance of radiologic and pathologic tumor size in breast carcinoma. (February 2019)
- Main Title:
- Factors affecting the concordance of radiologic and pathologic tumor size in breast carcinoma
- Authors:
- Hamza, Ameer
Khawar, Sidrah
Sakhi, Ramen
Alrajjal, Ahmed
Miller, Shelby
Ibrar, Warda
Edens, Jacob
Salehi, Sajad
Ockner, Daniel - Abstract:
- Background: Radiologic assessment of tumor size is an integral part of the work-up for breast carcinoma. With improved radiologic equipment, surgical decision relies profoundly upon radiologic/clinical stage. We wanted to see the concordance between radiologic and pathologic tumor size to infer how accurate radiologic/clinical staging is. Materials and methods: The surgical pathology and ultrasonography reports of patients with breast carcinoma were reviewed. Data were collected for 406 cases. Concordance was defined as a size difference within ±2 mm. Results: The difference between radiologic and pathologic tumor size was within ±2 mm in 40.4% cases. The mean radiologic size was 1.73 ± 1.06 cm. The mean pathologic size was 1.84 ± 1.24 cm. A paired t -test showed a significant mean difference between radiologic and pathologic measurements (0.12 ± 1.03 cm, p = 0.03). Despite the size difference, stage classification was the same in 59.9% of cases. Radiologic size overestimated stage in 14.5% of cases and underestimated stage in 25.6% of cases. The concordance rate was significantly higher for tumors ≤2 cm (pT1) (51.1%) as compared to those greater than 2 cm (≥pT2) (19.7%) ( p < 0.0001). Significantly more lumpectomy specimens (47.5%) had concordance when compared to mastectomy specimens (29.8%) ( p < 0.0001). Invasive ductal carcinoma had better concordance compared to other tumors ( p = 0.02). Conclusion: Mean pathologic tumor size was significantly different from meanBackground: Radiologic assessment of tumor size is an integral part of the work-up for breast carcinoma. With improved radiologic equipment, surgical decision relies profoundly upon radiologic/clinical stage. We wanted to see the concordance between radiologic and pathologic tumor size to infer how accurate radiologic/clinical staging is. Materials and methods: The surgical pathology and ultrasonography reports of patients with breast carcinoma were reviewed. Data were collected for 406 cases. Concordance was defined as a size difference within ±2 mm. Results: The difference between radiologic and pathologic tumor size was within ±2 mm in 40.4% cases. The mean radiologic size was 1.73 ± 1.06 cm. The mean pathologic size was 1.84 ± 1.24 cm. A paired t -test showed a significant mean difference between radiologic and pathologic measurements (0.12 ± 1.03 cm, p = 0.03). Despite the size difference, stage classification was the same in 59.9% of cases. Radiologic size overestimated stage in 14.5% of cases and underestimated stage in 25.6% of cases. The concordance rate was significantly higher for tumors ≤2 cm (pT1) (51.1%) as compared to those greater than 2 cm (≥pT2) (19.7%) ( p < 0.0001). Significantly more lumpectomy specimens (47.5%) had concordance when compared to mastectomy specimens (29.8%) ( p < 0.0001). Invasive ductal carcinoma had better concordance compared to other tumors ( p = 0.02). Conclusion: Mean pathologic tumor size was significantly different from mean radiologic tumor size. Concordance was in just over 40% of cases and the stage classification was the same in about 60% of cases only. Therefore, surgical decision of lumpectomy versus mastectomy based on radiologic tumor size may not always be accurate. … (more)
- Is Part Of:
- Ultrasound. Volume 27:Number 1(2019:Feb.)
- Journal:
- Ultrasound
- Issue:
- Volume 27:Number 1(2019:Feb.)
- Issue Display:
- Volume 27, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2019-0027-0001-0000
- Page Start:
- 45
- Page End:
- 54
- Publication Date:
- 2019-02
- Subjects:
- Breast carcinoma -- tumor size -- pathologic staging -- breast ultrasound -- concordance
Ultrasonic imaging -- Periodicals
Ultrasonography -- Periodicals
616.0754305 - Journal URLs:
- http://ult.sagepub.com/ ↗
http://www.maney.co.uk/search?fwaction=show&fwid=440 ↗
http://www.maney.co.uk/search?fwaction=show&fwid=440&fwprint=yes ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1742271X18804278 ↗
- Languages:
- English
- ISSNs:
- 1742-271X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9780.xml