Assessment of the Safety of the New Hybrid Pencil Type Energy (NP) Device Used Close to the Recurrent Laryngeal Nerve in a Porcine Model: Comparison With a Conventional Electrosurgical Knife. (April 2019)
- Record Type:
- Journal Article
- Title:
- Assessment of the Safety of the New Hybrid Pencil Type Energy (NP) Device Used Close to the Recurrent Laryngeal Nerve in a Porcine Model: Comparison With a Conventional Electrosurgical Knife. (April 2019)
- Main Title:
- Assessment of the Safety of the New Hybrid Pencil Type Energy (NP) Device Used Close to the Recurrent Laryngeal Nerve in a Porcine Model: Comparison With a Conventional Electrosurgical Knife
- Authors:
- Takeuchi, Masashi
Kawakubo, Hirofumi
Abe, Yuta
Kanazawa, Akishige
Ehara, Kazuhisa
Kinugasa, Yusuke
Kinoshita, Takahiro
Nomura, Akinari
Kitagawa, Yuko - Abstract:
- Background . Recurrent laryngeal nerve (RLN) paralysis is mainly associated with esophagectomy, and it may result in not only other morbidities, such as aspiration pneumonia, but also in long-term issues. Therefore, an approach to prevent RLN paralysis is necessary. The present study was designed to determine the technical usability of the new hybrid pencil type energy (NP) device developed by Olympus Corporation (Tokyo, Japan) and compare it with a conventional electrosurgical knife (EK) for resection around the RLN lymph nodes. Methods . This nonsurvival (acute) study included 10 pigs (20 RLNs) and investigated the threshold for thermal RLN damage with the NP device and a conventional EK. To obtain basic information for our study, a preliminary experiment for heat spread was performed. Results . When using the EK device, the amplitude value disappeared at a distance of 1 mm from the RLN, but when using the NP device, the amplitude value was maintained up to a distance of 0.5 mm. There were significant differences at distances of 0 mm, 0.5 mm, and 1 mm between the NP and EK devices. Furthermore, heat spread was lower with the NP device than with the EK device. Conclusions . The new energy device developed by Olympus Corporation was found to be technically safe for resection of the RLN lymph nodes in a porcine model. To the best of our knowledge, this is the first study to demonstrate the potential advantages of using this new energy device in a clinical aspect.
- Is Part Of:
- Surgical innovation. Volume 26:Number 2(2019)
- Journal:
- Surgical innovation
- Issue:
- Volume 26:Number 2(2019)
- Issue Display:
- Volume 26, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 2
- Issue Sort Value:
- 2019-0026-0002-0000
- Page Start:
- 219
- Page End:
- 226
- Publication Date:
- 2019-04
- Subjects:
- recurrent laryngeal nerve -- device -- combined energy -- porcine
Surgery, Operative -- Periodicals
Endoscopic surgery -- Periodicals
Laparoscopic surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Diffusion of Innovation -- Periodicals
Chirurgie opératoire -- Périodiques
Chirurgie endoscopique -- Périodiques
Chirurgie laparoscopique -- Périodiques
617.91 - Journal URLs:
- http://journals.sagepub.com/home/sri ↗
http://sri.sagepub.com/ ↗
http://www.sagepub.com/journalsProdDesc.nav?prodId=Journal201793 ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1553350618817646 ↗
- Languages:
- English
- ISSNs:
- 1553-3506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: