Does an inverted pendulum model represent the gait of individuals with unilateral transfemoral amputation while walking over level ground?. (April 2019)
- Record Type:
- Journal Article
- Title:
- Does an inverted pendulum model represent the gait of individuals with unilateral transfemoral amputation while walking over level ground?. (April 2019)
- Main Title:
- Does an inverted pendulum model represent the gait of individuals with unilateral transfemoral amputation while walking over level ground?
- Authors:
- Strutzenberger, Gerda
Alexander, Nathalie
De Asha, Alan
Schwameder, Hermann
Barnett, Cleveland Thomas - Abstract:
- Background: An inverted pendulum model represents the mechanical function of able-bodied individuals walking accurately, with centre of mass height and forward velocity data plotting as sinusoidal curves, 180° out of phase. Objectives: This study investigated whether the inverted pendulum model represented level gait in individuals with a unilateral transfemoral amputation. Study Design: Controlled trial. Methods: Kinematic and kinetic data from 10 individuals with unilateral transfemoral amputation and 15 able-bodied participants were recorded during level walking. Results: During level walking, the inverted pendulum model described able-bodied gait well throughout the gait cycle, with median relative time shifts between centre of mass height and velocity maxima and minima between 1.2% and 1.8% of gait cycle. In the group with unilateral transfemoral amputation, the relative time shift was significantly increased during the prosthetic-limb initial double-limb support phase by 6.3%. Conclusion: The gait of individuals with unilateral transfemoral amputation shows deviation from a synchronous inverted pendulum model during prosthetic-limb stance. The reported divergence may help explain such individuals' increased metabolic cost of gait. Temporal divergence of inverted pendulum behaviour could potentially be utilised as a tool to assess the efficacy of prosthetic device prescription. Clinical relevance: The size of the relative time shifts between centre of mass height andBackground: An inverted pendulum model represents the mechanical function of able-bodied individuals walking accurately, with centre of mass height and forward velocity data plotting as sinusoidal curves, 180° out of phase. Objectives: This study investigated whether the inverted pendulum model represented level gait in individuals with a unilateral transfemoral amputation. Study Design: Controlled trial. Methods: Kinematic and kinetic data from 10 individuals with unilateral transfemoral amputation and 15 able-bodied participants were recorded during level walking. Results: During level walking, the inverted pendulum model described able-bodied gait well throughout the gait cycle, with median relative time shifts between centre of mass height and velocity maxima and minima between 1.2% and 1.8% of gait cycle. In the group with unilateral transfemoral amputation, the relative time shift was significantly increased during the prosthetic-limb initial double-limb support phase by 6.3%. Conclusion: The gait of individuals with unilateral transfemoral amputation shows deviation from a synchronous inverted pendulum model during prosthetic-limb stance. The reported divergence may help explain such individuals' increased metabolic cost of gait. Temporal divergence of inverted pendulum behaviour could potentially be utilised as a tool to assess the efficacy of prosthetic device prescription. Clinical relevance: The size of the relative time shifts between centre of mass height and velocity maxima and minima could potentially be used as a tool to quantify the efficacy of innovative prosthetic device design features aimed at reducing the metabolic cost of walking and improving gait efficiency in individuals with amputation. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 43:Number 2(2019)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 43:Number 2(2019)
- Issue Display:
- Volume 43, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2019-0043-0002-0000
- Page Start:
- 221
- Page End:
- 226
- Publication Date:
- 2019-04
- Subjects:
- Gait -- prosthetics -- centre of mass velocity -- centre of mass height -- mechanistic gait model
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364618796847 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9759.xml