The LAMB gait analysis protocol: Definition and experimental assessment of operator-related variability. (March 2019)
- Record Type:
- Journal Article
- Title:
- The LAMB gait analysis protocol: Definition and experimental assessment of operator-related variability. (March 2019)
- Main Title:
- The LAMB gait analysis protocol: Definition and experimental assessment of operator-related variability
- Authors:
- Rabuffetti, Marco
Marzegan, Alberto
Crippa, Alessandro
Carpinella, Ilaria
Lencioni, Tiziana
Castagna, Anna
Ferrarin, Maurizio - Abstract:
- Gait analysis has demonstrated to efficaciously support clinical investigations. The patterns of the outcome variables (joint angles, moments and powers) are characterized by an intrinsic and extrinsic variability. Particularly, extrinsic variability is induced by operator-dependent differences in markers' placement, with errors propagating non-linearly to alter outcome variable patterns. The aims of this study are (1) to consider a specific gait analysis protocol named LAMB and provide a description of its procedures, (2) to experimentally assess the between-operator and within-operator variability induced by operator-dependent marking of required anatomical landmarks and (3) to evidence how such inaccuracies propagates to the gait analysis kinematic and kinetic outcome variables. Six expert gait analysis operators performed LAMB anatomical landmarks marking on three healthy adult participants; moreover, one operator repeated three times the marking on one participant. The participants then performed a set of locomotor tasks including stair negotiation and heel- and toe-walking. An anatomical calibration approach let to register each marking and to compute, starting from one single raw data set, a set of outcome variables for each marking/operator. The between-operator variability of gait analysis outcome was assessed in terms of mean absolute variability to quantify offsets and minimal correlation coefficient to quantify patterns' similarity. The results evidence averageGait analysis has demonstrated to efficaciously support clinical investigations. The patterns of the outcome variables (joint angles, moments and powers) are characterized by an intrinsic and extrinsic variability. Particularly, extrinsic variability is induced by operator-dependent differences in markers' placement, with errors propagating non-linearly to alter outcome variable patterns. The aims of this study are (1) to consider a specific gait analysis protocol named LAMB and provide a description of its procedures, (2) to experimentally assess the between-operator and within-operator variability induced by operator-dependent marking of required anatomical landmarks and (3) to evidence how such inaccuracies propagates to the gait analysis kinematic and kinetic outcome variables. Six expert gait analysis operators performed LAMB anatomical landmarks marking on three healthy adult participants; moreover, one operator repeated three times the marking on one participant. The participants then performed a set of locomotor tasks including stair negotiation and heel- and toe-walking. An anatomical calibration approach let to register each marking and to compute, starting from one single raw data set, a set of outcome variables for each marking/operator. The between-operator variability of gait analysis outcome was assessed in terms of mean absolute variability to quantify offsets and minimal correlation coefficient to quantify patterns' similarity. The results evidence average minimal correlation coefficient ranging from 0.857 for moments to 0.907 for angles and average mean absolute variability accounted for few degrees in angular variables (worst between-operator mean absolute variability is 7.3°), while dynamic variables mean absolute variability, relative to the variable range, was below 5% for moment and below 10% for powers. The variability indexes are comparable to those related to previously published protocols and are independent from the considered task, thus suggesting that the LAMB is a reliable protocol suitable for the analysis of different locomotor tasks. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 233:Number 3(2019)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 233:Number 3(2019)
- Issue Display:
- Volume 233, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 233
- Issue:
- 3
- Issue Sort Value:
- 2019-0233-0003-0000
- Page Start:
- 342
- Page End:
- 353
- Publication Date:
- 2019-03
- Subjects:
- Gait analysis -- biomechanical testing/analysis -- photogrammetry/stereo-photogrammetry -- motion analysis systems -- variability
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411919827033 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9758.xml