Seat belts‐related behaviors in car drivers with cardiac implantable electronic devices. Issue 4 (18th February 2019)
- Record Type:
- Journal Article
- Title:
- Seat belts‐related behaviors in car drivers with cardiac implantable electronic devices. Issue 4 (18th February 2019)
- Main Title:
- Seat belts‐related behaviors in car drivers with cardiac implantable electronic devices
- Authors:
- Niewinski, Piotr
Jagielski, Dariusz
Josiak, Krystian
Nowak, Krzysztof
Biel, Bartosz
Tubek, Stanislaw
Walczak, Tomasz
Szemplinska, Iwona
Siennicka, Agnieszka
Banasiak, Waldemar
Ponikowski, Piotr - Abstract:
- Abstract: Background: Seat belt use is the single most effective means of reducing fatal injuries in road traffic accidents. The presence of a cardiac implantable electronic device (CIED) might influence seat belt‐related behaviors due to the physical proximity of the seat belt and left subclavian area in which the device is usually implanted. Understanding the underlying mechanisms of improper seat belt use may improve safety of these patients. Methods: We performed a prospective study using a structured questionnaire with 120 CIED recipients (age, 63.9 ± 10.9 years) attending a pacing outpatient clinic. All study participants were active drivers and predominantly male. The majority of patients (79%) had undergone high‐energy device implantation. Results: We found that 18% of study participants do not fasten seat belts on a regular basis or use the seat belt in an atypical fashion (such as under the armpit). Moderate or high level of discomfort from the interaction between seat belt and CIED was present in 27%, while more than half (51%) were afraid of seat belt‐induced CIED damage. In multifactorial analysis, we found the following independent predictors of improper seat belt use: (1) at least moderate level of discomfort at the CIED site ( P = 0.02); (2) fear of CIED damage ( P = 0.009); and (3) irregular seat belt use prior to CIED implantation ( P = 0.037). Conclusions: Improper seat belt‐related behaviors are common in CIED recipients. They arise from previousAbstract: Background: Seat belt use is the single most effective means of reducing fatal injuries in road traffic accidents. The presence of a cardiac implantable electronic device (CIED) might influence seat belt‐related behaviors due to the physical proximity of the seat belt and left subclavian area in which the device is usually implanted. Understanding the underlying mechanisms of improper seat belt use may improve safety of these patients. Methods: We performed a prospective study using a structured questionnaire with 120 CIED recipients (age, 63.9 ± 10.9 years) attending a pacing outpatient clinic. All study participants were active drivers and predominantly male. The majority of patients (79%) had undergone high‐energy device implantation. Results: We found that 18% of study participants do not fasten seat belts on a regular basis or use the seat belt in an atypical fashion (such as under the armpit). Moderate or high level of discomfort from the interaction between seat belt and CIED was present in 27%, while more than half (51%) were afraid of seat belt‐induced CIED damage. In multifactorial analysis, we found the following independent predictors of improper seat belt use: (1) at least moderate level of discomfort at the CIED site ( P = 0.02); (2) fear of CIED damage ( P = 0.009); and (3) irregular seat belt use prior to CIED implantation ( P = 0.037). Conclusions: Improper seat belt‐related behaviors are common in CIED recipients. They arise from previous habits and from CIED‐related physical and psychological factors. Patients' education regarding the importance and safety of proper seat belt use is a priority. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 4(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 4(2019)
- Issue Display:
- Volume 42, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2019-0042-0004-0000
- Page Start:
- 400
- Page End:
- 406
- Publication Date:
- 2019-02-18
- Subjects:
- CRT‐D -- ICD -- pacemaker -- seat belts
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13617 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9744.xml