Multi‐observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest. Issue 2 (4th January 2019)
- Record Type:
- Journal Article
- Title:
- Multi‐observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest. Issue 2 (4th January 2019)
- Main Title:
- Multi‐observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest
- Authors:
- Roach, Dale
Holloway, Lois C
Jameson, Michael G
Dowling, Jason A
Kennedy, Angel
Greer, Peter B
Krawiec, Michele
Rai, Robba
Denham, Jim
De Leon, Jeremiah
Lim, Karen
Berry, Megan E
White, Rohen T
Bydder, Sean A
Tan, Hendrick T
Croker, Jeremy D
McGrath, Alycea
Matthews, John
Smeenk, Robert J
Ebert, Martin A - Abstract:
- Abstract: Introduction: This study quantified inter‐observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies. Methods: Five prostate cancer patient datasets (CT and T2‐weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri‐rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics. Results: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter‐observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter‐observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15).Abstract: Introduction: This study quantified inter‐observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies. Methods: Five prostate cancer patient datasets (CT and T2‐weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri‐rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics. Results: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter‐observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter‐observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter‐observer agreement (ICC = 0.50–0.97), although large outlier variations were observed. Conclusions: Inter‐observer contouring variation was significant for multiple pelvic structures contoured on MR. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 63:Issue 2(2019:Apr.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 63:Issue 2(2019:Apr.)
- Issue Display:
- Volume 63, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 63
- Issue:
- 2
- Issue Sort Value:
- 2019-0063-0002-0000
- Page Start:
- 264
- Page End:
- 271
- Publication Date:
- 2019-01-04
- Subjects:
- contouring -- delineation -- inter/intra‐observer variability -- prostate
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12844 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9742.xml