A multiparametric method to assess the MIM deformable image registration algorithm. Issue 4 (28th March 2019)
- Record Type:
- Journal Article
- Title:
- A multiparametric method to assess the MIM deformable image registration algorithm. Issue 4 (28th March 2019)
- Main Title:
- A multiparametric method to assess the MIM deformable image registration algorithm
- Authors:
- Calusi, Silvia
Labanca, Giusy
Zani, Margherita
Casati, Marta
Marrazzo, Livia
Noferini, Linhsia
Talamonti, Cinzia
Fusi, Franco
Desideri, Isacco
Bonomo, Pierluigi
Livi, Lorenzo
Pallotta, Stefania - Abstract:
- Abstract: A quantitative evaluation of the performances of the deformable image registration (DIR) algorithm implemented in MIM‐Maestro was performed using multiple similarity indices. Two phantoms, capable of mimicking different anatomical bending and tumor shrinking were built and computed tomography (CT) studies were acquired after applying different deformations. Three different contrast levels between internal structures were artificially created modifying the original CT values of one dataset. DIR algorithm was applied between datasets with increasing deformations and different contrast levels and manually refined with the Reg Refine tool. DIR algorithm ability in reproducing positions, volumes, and shapes of deformed structures was evaluated using similarity indices such as: landmark distances, Dice coefficients, Hausdorff distances, and maximum diameter differences between segmented structures. Similarity indices values worsen with increasing bending and volume difference between reference and target image sets. Registrations between images with low contrast (40 HU) obtain scores lower than those between images with high contrast (970 HU). The use of Reg Refine tool leads generally to an improvement of similarity parameters values, but the advantage is generally less evident for images with low contrast or when structures with large volume differences are involved. The dependence of DIR algorithm on image deformation extent and different contrast levels is wellAbstract: A quantitative evaluation of the performances of the deformable image registration (DIR) algorithm implemented in MIM‐Maestro was performed using multiple similarity indices. Two phantoms, capable of mimicking different anatomical bending and tumor shrinking were built and computed tomography (CT) studies were acquired after applying different deformations. Three different contrast levels between internal structures were artificially created modifying the original CT values of one dataset. DIR algorithm was applied between datasets with increasing deformations and different contrast levels and manually refined with the Reg Refine tool. DIR algorithm ability in reproducing positions, volumes, and shapes of deformed structures was evaluated using similarity indices such as: landmark distances, Dice coefficients, Hausdorff distances, and maximum diameter differences between segmented structures. Similarity indices values worsen with increasing bending and volume difference between reference and target image sets. Registrations between images with low contrast (40 HU) obtain scores lower than those between images with high contrast (970 HU). The use of Reg Refine tool leads generally to an improvement of similarity parameters values, but the advantage is generally less evident for images with low contrast or when structures with large volume differences are involved. The dependence of DIR algorithm on image deformation extent and different contrast levels is well characterized through the combined use of multiple similarity indices. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 4(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 4(2019)
- Issue Display:
- Volume 20, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2019-0020-0004-0000
- Page Start:
- 75
- Page End:
- 82
- Publication Date:
- 2019-03-28
- Subjects:
- bending and shrinking -- deformable image registration -- deformable phantom -- DIR algorithm accuracy assessment -- similarity indices
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12564 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9733.xml