Inter-rater reliability of the radiographic assessment of simple bone cysts. (1st April 2019)
- Record Type:
- Journal Article
- Title:
- Inter-rater reliability of the radiographic assessment of simple bone cysts. (1st April 2019)
- Main Title:
- Inter-rater reliability of the radiographic assessment of simple bone cysts
- Authors:
- Cho, S.
Yankanah, R.
Babyn, P.
Stimec, J.
Doria, A. S.
Stephens, D.
Wright, J. G. - Abstract:
- Abstract: Purpose: To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods Methods: Radiographic criteria were developed based on the literature and expert consensus. A single anteroposterior/lateral radiograph from 32 subjects with SBC were evaluated by three radiologists. A second reading was then conducted using revised criteria including a visual schematic. In the third reading the same images were assessed but radiologists had access to images from two additional time points. Inter-rater reliability was assessed after each reading using kappa (κ) and percentage agreement for categorical and binary parameters and intra-class correlation coefficient (ICC) for continuous parameters. Results: Parameters that were revised with more explicit definitions including the visual schematic demonstrated consistent or improved inter-rater reliability with the exception of continuous cortical rim present and cyst location in the metaphysis and mid-diaphysis. Cortical rim displayed only slight reliability throughout (κ= -0.008 to 0.16). All other categorical parameters had a percentage agreement above 0.8 or a moderate (κ= 0.41 to 0.60), substantial (κ = 0.61 to 0.80) or almost perfect inter-rater reliability (κ = 0.81 to 1.0) in at least one reading. All continuous parameters demonstrated excellent inter-rater reliability (ICC > 0.75) in atAbstract: Purpose: To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods Methods: Radiographic criteria were developed based on the literature and expert consensus. A single anteroposterior/lateral radiograph from 32 subjects with SBC were evaluated by three radiologists. A second reading was then conducted using revised criteria including a visual schematic. In the third reading the same images were assessed but radiologists had access to images from two additional time points. Inter-rater reliability was assessed after each reading using kappa (κ) and percentage agreement for categorical and binary parameters and intra-class correlation coefficient (ICC) for continuous parameters. Results: Parameters that were revised with more explicit definitions including the visual schematic demonstrated consistent or improved inter-rater reliability with the exception of continuous cortical rim present and cyst location in the metaphysis and mid-diaphysis. Cortical rim displayed only slight reliability throughout (κ= -0.008 to 0.16). All other categorical parameters had a percentage agreement above 0.8 or a moderate (κ= 0.41 to 0.60), substantial (κ = 0.61 to 0.80) or almost perfect inter-rater reliability (κ = 0.81 to 1.0) in at least one reading. All continuous parameters demonstrated excellent inter-rater reliability (ICC > 0.75) in at least one reading with the exception of scalloping (ICC = 0.37 to 0.70). Inter-rater reliability values did not indicate an obviously superior method of assessment between single and serial chronological readings. Conclusion: Explicit criteria for SBC parameters used in their assessment demonstrated improved and substantial inter-rater reliability. Inter-rater reliability did not differ between single and serial chronological readings. Level of Evidence: Not Applicable … (more)
- Is Part Of:
- Journal of children's orthopaedics. Volume 13:Number 2(2019)
- Journal:
- Journal of children's orthopaedics
- Issue:
- Volume 13:Number 2(2019)
- Issue Display:
- Volume 13, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 13
- Issue:
- 2
- Issue Sort Value:
- 2019-0013-0002-0000
- Page Start:
- 226
- Page End:
- 235
- Publication Date:
- 2019-04-01
- Subjects:
- simple bone cyst -- unicameral bone cyst -- bone cyst -- inter-rater reliability -- radiography
Pediatric orthopedics -- Periodicals
618.927005 - Journal URLs:
- http://link.springer.com/journal/11832 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/842/ ↗
http://www.springerlink.com/content/120451/ ↗
https://online.boneandjoint.org.uk/toc/jco/current ↗
https://journals.sagepub.com/home/CHO ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1302/1863-2548.13.180140 ↗
- Languages:
- English
- ISSNs:
- 1863-2521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4957.960000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9732.xml