Does deep inspiration breath hold reduce plan complexity? Multicentric experience of left breast cancer radiotherapy with volumetric modulated arc therapy. (March 2019)
- Record Type:
- Journal Article
- Title:
- Does deep inspiration breath hold reduce plan complexity? Multicentric experience of left breast cancer radiotherapy with volumetric modulated arc therapy. (March 2019)
- Main Title:
- Does deep inspiration breath hold reduce plan complexity? Multicentric experience of left breast cancer radiotherapy with volumetric modulated arc therapy
- Authors:
- Russo, Serenella
Esposito, Marco
Hernandez, Victor
Saez, Jordi
Rossi, Francesca
Paoletti, Lisa
Pini, Silvia
Bastiani, Paolo
Reggiori, Giacomo
Nicolini, Giorgia
Vanetti, Eugenio
Tomatis, Stefano
Scorsetti, Marta
Mancosu, Pietro - Abstract:
- Highlights: A multicenter comparison between FB and DIBH VMAT breast plans was conducted. VMAT-DIBH plans allow to significantly reduce OARs doses and to improve target coverage. The cardiac-sparing benefits of the DIBH plans were achieved with a lower plan complexity than FB. A new global score index accounting for both plan quality and dosimetric parameters was defined. All plans verifications produced satisfactory QA results. Abstract: Purpose: Volumetric modulated arc therapy (VMAT) for left breast treatments allows heart sparing without compromising PTV coverage. However, this technique may require highly complex plans. Deep Inspiration Breath Hold (DIBH) procedure increases the heart-to-breast distance, facilitating the dose sparing of the heart. The aim of the present work was to investigate if the cardiac-sparing benefits of the DIBH technique were achieved with lower plan modulation and complexity than Free Breathing (FB) treatments. Methods and materials: Ten left side breast cases were considered by two centers with different treatment planning systems (TPS) and Linacs. VMAT plans were elaborated in FB and DIBH according to the same protocol. Plan complexity was evaluated by scoring several complexity indices. A new global score index accounting for both plan quality and dosimetric parameters was defined. Pre-treatment QA was performed for all VMAT plans using EPID and Epiqa software. Results: DIBH-VMAT plans were associated with significant PTV coverageHighlights: A multicenter comparison between FB and DIBH VMAT breast plans was conducted. VMAT-DIBH plans allow to significantly reduce OARs doses and to improve target coverage. The cardiac-sparing benefits of the DIBH plans were achieved with a lower plan complexity than FB. A new global score index accounting for both plan quality and dosimetric parameters was defined. All plans verifications produced satisfactory QA results. Abstract: Purpose: Volumetric modulated arc therapy (VMAT) for left breast treatments allows heart sparing without compromising PTV coverage. However, this technique may require highly complex plans. Deep Inspiration Breath Hold (DIBH) procedure increases the heart-to-breast distance, facilitating the dose sparing of the heart. The aim of the present work was to investigate if the cardiac-sparing benefits of the DIBH technique were achieved with lower plan modulation and complexity than Free Breathing (FB) treatments. Methods and materials: Ten left side breast cases were considered by two centers with different treatment planning systems (TPS) and Linacs. VMAT plans were elaborated in FB and DIBH according to the same protocol. Plan complexity was evaluated by scoring several complexity indices. A new global score index accounting for both plan quality and dosimetric parameters was defined. Pre-treatment QA was performed for all VMAT plans using EPID and Epiqa software. Results: DIBH-VMAT plans were associated with significant PTV coverage improvement and mean heart dose reduction (p < 0.003), increasing the resulting global score index. All the evaluated complexity indices showed lower plan complexity for DIBH plans than FB ones, but only in few cases the results were statistically significant. All plans passed the gamma analysis with the selected criteria. Conclusions: The DIBH technique is superior to the FB technique when the heart needs further sparing, allowing a reduction of the doses to OARs with a slightly lower degree of plan complexity and without compromising plan deliverability. These benefits were achieved regardless of the technological scenarios adopted. … (more)
- Is Part Of:
- Physica medica. Volume 59(2019)
- Journal:
- Physica medica
- Issue:
- Volume 59(2019)
- Issue Display:
- Volume 59, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 2019
- Issue Sort Value:
- 2019-0059-2019-0000
- Page Start:
- 79
- Page End:
- 85
- Publication Date:
- 2019-03
- Subjects:
- Left breast -- VMAT -- DIBH -- Complexity index
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.02.018 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9738.xml