Successful inferior vena cava filter removal using pacemaker lead extraction methods. Issue 4 (April 2019)
- Record Type:
- Journal Article
- Title:
- Successful inferior vena cava filter removal using pacemaker lead extraction methods. Issue 4 (April 2019)
- Main Title:
- Successful inferior vena cava filter removal using pacemaker lead extraction methods
- Authors:
- Itagaki, Tadashi
Okada, Ayako
Tabata, Hiroaki
Shoin, Wataru
Kobayashi, Hideki
Okano, Takahiro
Oguchi, Yasutaka
Mochidome, Tomoaki
Saigusa, Tatsuya
Ebisawa, Soichiro
Motoki, Hirohiko
Shoda, Morio
Kuwahara, Koichiro - Abstract:
- Abstract: Inferior vena cava (IVC) filters are often used to treat deep vein thrombosis. IVC filters may become difficult to extract because of adhesion around the device, and those permanently left inside the patient may cause injurious complications. We describe a novel IVC filter extraction technique using pacemaker lead extraction tools. A 26-year-old woman, diagnosed with deep vein thrombosis by computed tomography, received an IVC filter (Gunther Tulip, Cook Medical, Bloomington, IN, USA) implantation for prevention of pulmonary thromboembolism. Eleven weeks later, extraction of the IVC filter by a manual method and snaring technique was unsuccessful because of adhesion to the blood vessel wall. The patient was referred to our hospital for filter removal using pacemaker lead extraction tools. Extraction was performed in an operation room under general anesthesia in the presence of a cardiovascular surgeon, to manage inadvertent perforation. Part of the adhered tissue around the four limbs of the filter was dissected using a 12 Fr laser sheath; protruding anchors were carefully dissected with a telescoping mechanical sheath using a counter-traction technique. Her postoperative course was uneventful, and she was discharged without complications. A sophisticated removal procedure with pacemaker lead extraction tools can be used to remove problematic IVC filters. <Learning objective: Inferior vena cava (IVC) filters are often used to treat deep vein thrombosis. AlthoughAbstract: Inferior vena cava (IVC) filters are often used to treat deep vein thrombosis. IVC filters may become difficult to extract because of adhesion around the device, and those permanently left inside the patient may cause injurious complications. We describe a novel IVC filter extraction technique using pacemaker lead extraction tools. A 26-year-old woman, diagnosed with deep vein thrombosis by computed tomography, received an IVC filter (Gunther Tulip, Cook Medical, Bloomington, IN, USA) implantation for prevention of pulmonary thromboembolism. Eleven weeks later, extraction of the IVC filter by a manual method and snaring technique was unsuccessful because of adhesion to the blood vessel wall. The patient was referred to our hospital for filter removal using pacemaker lead extraction tools. Extraction was performed in an operation room under general anesthesia in the presence of a cardiovascular surgeon, to manage inadvertent perforation. Part of the adhered tissue around the four limbs of the filter was dissected using a 12 Fr laser sheath; protruding anchors were carefully dissected with a telescoping mechanical sheath using a counter-traction technique. Her postoperative course was uneventful, and she was discharged without complications. A sophisticated removal procedure with pacemaker lead extraction tools can be used to remove problematic IVC filters. <Learning objective: Inferior vena cava (IVC) filters are often used to treat deep vein thrombosis. Although IVC filters are temporary implants, they may become difficult to extract because of adhesion around the device. Many IVC filters that cannot be retrieved are permanently left inside the patient, which may cause injurious complications. We describe a novel IVC filter extraction technique using pacemaker lead extraction tools, and this technique can be helpful for the management of problematic IVC filters.> … (more)
- Is Part Of:
- Journal of cardiology cases. Volume 19:Issue 4(2019)
- Journal:
- Journal of cardiology cases
- Issue:
- Volume 19:Issue 4(2019)
- Issue Display:
- Volume 19, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 19
- Issue:
- 4
- Issue Sort Value:
- 2019-0019-0004-0000
- Page Start:
- 129
- Page End:
- 132
- Publication Date:
- 2019-04
- Subjects:
- Inferior vena cava filter -- Deep vein thrombosis -- Pacemaker lead extraction methods -- Excimer laser -- Mechanical sheath
Cardiology -- Periodicals
Cardiovascular Diseases -- Case Reports
Cardiovascular Diseases -- Periodicals
Cardiology -- Case Reports
Cardiology -- Periodicals
Cardiology
Electronic journals
Periodicals
616.12 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18785409 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/18785409 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jccase.2018.12.012 ↗
- Languages:
- English
- ISSNs:
- 1878-5409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9735.xml