Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols. Issue 113 (April 2019)
- Record Type:
- Journal Article
- Title:
- Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols. Issue 113 (April 2019)
- Main Title:
- Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols
- Authors:
- Al-Murshedi, Sadeq
Hogg, Peter
Meijer, Annemieke
Erenstein, Hendrik
England, Andrew - Abstract:
- Highlights: 1-Considerable difference in IQ and dose exist for paediatric CXRs between hospitals. 2-Differences exist in paediatric CXR protocols different between hospitals. 3-Routine paediatric CXRs protocols require further optimisation. Abstract: Objectives: To compare low contrast detail (LCD) detectability and radiation dose for routine paediatric chest X-ray (CXR) imaging protocols among various hospitals. Methods: CDRAD 2.0 phantom and medical grade polymethyl methacrylate (PMMA) slabs were used to simulate the chest region of four different paediatric age groups. Radiographic acquisitions were undertaken on 17 X-ray machines located in eight hospitals using their existing CXR protocols. LCD detectability represented by image quality figure inverse (IQFinv ) was measured physically using the CDRAD analyser software. Incident air kerma (IAK) measurements were obtained using a solid-state dosimeter. Results: The range of IQFinv, between and within the hospitals, was 1.40–4.44 and 1.52–2.18, respectively for neonates; 0.96–4.73 and 2.33–4.73 for a 1-year old; 0.87–1.81 and 0.98–1.46 for a 5-year old and 0.90–2.39 and 1.27–2.39 for a 10-year old. The range of IAK, between and within the hospitals, was 8.56–52.62 μGy and 21.79–52.62 μGy, respectively for neonates; 5.44–82.82 μGy and 36.78–82.82 μGy for a 1-year old; 10.97–59.22 μGy and 11.75–52.94 μGy for a 5-year old and 13.97–100.77 μGy and 35.72–100.77 μGy for a 10-year old. Conclusions: Results show considerableHighlights: 1-Considerable difference in IQ and dose exist for paediatric CXRs between hospitals. 2-Differences exist in paediatric CXR protocols different between hospitals. 3-Routine paediatric CXRs protocols require further optimisation. Abstract: Objectives: To compare low contrast detail (LCD) detectability and radiation dose for routine paediatric chest X-ray (CXR) imaging protocols among various hospitals. Methods: CDRAD 2.0 phantom and medical grade polymethyl methacrylate (PMMA) slabs were used to simulate the chest region of four different paediatric age groups. Radiographic acquisitions were undertaken on 17 X-ray machines located in eight hospitals using their existing CXR protocols. LCD detectability represented by image quality figure inverse (IQFinv ) was measured physically using the CDRAD analyser software. Incident air kerma (IAK) measurements were obtained using a solid-state dosimeter. Results: The range of IQFinv, between and within the hospitals, was 1.40–4.44 and 1.52–2.18, respectively for neonates; 0.96–4.73 and 2.33–4.73 for a 1-year old; 0.87–1.81 and 0.98–1.46 for a 5-year old and 0.90–2.39 and 1.27–2.39 for a 10-year old. The range of IAK, between and within the hospitals, was 8.56–52.62 μGy and 21.79–52.62 μGy, respectively for neonates; 5.44–82.82 μGy and 36.78–82.82 μGy for a 1-year old; 10.97–59.22 μGy and 11.75–52.94 μGy for a 5-year old and 13.97–100.77 μGy and 35.72–100.77 μGy for a 10-year old. Conclusions: Results show considerable variation, between and within hospitals, in the LCD detectability and IAK. Further radiation dose optimisation for the four paediatric age groups, especially in hospitals /X-ray rooms with low LCD detectability and high IAK, are required. … (more)
- Is Part Of:
- European journal of radiology. Issue 113(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 113(2019)
- Issue Display:
- Volume 113, Issue 113 (2019)
- Year:
- 2019
- Volume:
- 113
- Issue:
- 113
- Issue Sort Value:
- 2019-0113-0113-0000
- Page Start:
- 198
- Page End:
- 203
- Publication Date:
- 2019-04
- Subjects:
- Paediatric chest radiography -- CDRAD phantom -- Low contrast detail detectability and radiation dose
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.02.017 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9739.xml