A platform for patient positioning and motion monitoring in ocular proton therapy with a non-dedicated beamline. (March 2019)
- Record Type:
- Journal Article
- Title:
- A platform for patient positioning and motion monitoring in ocular proton therapy with a non-dedicated beamline. (March 2019)
- Main Title:
- A platform for patient positioning and motion monitoring in ocular proton therapy with a non-dedicated beamline
- Authors:
- Via, Riccardo
Pella, Andrea
Romanò, Francesco
Fassi, Aurora
Ricotti, Rosalinda
Tagaste, Barbara
Vai, Alessandro
Mastella, Edoardo
Rosaria Fiore, Maria
Valvo, Francesca
Ciocca, Mario
Baroni, Guido - Abstract:
- Highlights: A general-purpose beamline was adapted to treat intraocular tumors with proton. Novel strategies for patient positioning and motion monitoring were applied. The proposed technologies comply with the strict accuracy requirement of ocular proton therapy. The results show accuracy in patient positioning comparable to centers equipped with dedicated technologies. Abstract: Purpose: At Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy) ocular proton therapy (OPT) is delivered using a non-dedicated beamline. This paper describes the novel clinical workflow as well as technologies and methods adopted to achieve accurate target positioning and verification during ocular proton therapy at CNAO. Method: The OPT clinical protocol at CNAO prescribes a treatment simulation and a delivery phase, performed in the CT and treatment rooms, respectively. The patient gaze direction is controlled and monitored during the entire workflow by means of an eye tracking system (ETS) featuring two optical cameras and an embedded fixation diode light. Thus, the accurate alignment of the fixation light provided to the patient to the prescribed gazed direction is required for an effective treatment. As such, a technological platform based on active robotic manipulators and IR optical tracking-based guidance was developed and tested. The effectiveness of patient positioning strategies was evaluated on a clinical dataset comprising twenty patients treated at CNAO. Results: AccordingHighlights: A general-purpose beamline was adapted to treat intraocular tumors with proton. Novel strategies for patient positioning and motion monitoring were applied. The proposed technologies comply with the strict accuracy requirement of ocular proton therapy. The results show accuracy in patient positioning comparable to centers equipped with dedicated technologies. Abstract: Purpose: At Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy) ocular proton therapy (OPT) is delivered using a non-dedicated beamline. This paper describes the novel clinical workflow as well as technologies and methods adopted to achieve accurate target positioning and verification during ocular proton therapy at CNAO. Method: The OPT clinical protocol at CNAO prescribes a treatment simulation and a delivery phase, performed in the CT and treatment rooms, respectively. The patient gaze direction is controlled and monitored during the entire workflow by means of an eye tracking system (ETS) featuring two optical cameras and an embedded fixation diode light. Thus, the accurate alignment of the fixation light provided to the patient to the prescribed gazed direction is required for an effective treatment. As such, a technological platform based on active robotic manipulators and IR optical tracking-based guidance was developed and tested. The effectiveness of patient positioning strategies was evaluated on a clinical dataset comprising twenty patients treated at CNAO. Results: According to experimental testing, the developed technologies guarantee uncertainties lower than one degree in gaze direction definition by means of ETS-guided positioning. Patient positioning and monitoring strategies during treatment effectively mitigated set-up uncertainties and exhibited sub-millimetric accuracy in radiopaque markers alignment. Conclusion: Ocular proton therapy is currently delivered at CNAO with a non-dedicated beamline. The technologies developed for patient positioning and motion monitoring have proven to be compliant with the high geometrical accuracy required for the treatment of intraocular tumors. … (more)
- Is Part Of:
- Physica medica. Volume 59(2019)
- Journal:
- Physica medica
- Issue:
- Volume 59(2019)
- Issue Display:
- Volume 59, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 2019
- Issue Sort Value:
- 2019-0059-2019-0000
- Page Start:
- 55
- Page End:
- 63
- Publication Date:
- 2019-03
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.02.020 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9738.xml