Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters. Issue 113 (April 2019)
- Record Type:
- Journal Article
- Title:
- Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters. Issue 113 (April 2019)
- Main Title:
- Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters
- Authors:
- Wang, Nan
Ju, Ye
Wu, Jingjun
Liu, Ailian
Chen, Anliang
Liu, Jinghong
Liu, Yijun
Li, Jianying - Abstract:
- Abstract: Objective: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor. Methods: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40–140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t -test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed. Results: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrationsAbstract: Objective: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor. Methods: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40–140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t -test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed. Results: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrations in the plain phase and NIC in the contrast-enhanced venous and delay phases between liver abscesses and liver metastases (all P < 0.05). The CT value at 40 keV in the plain phase provided 0.761 in area under the curve (AUC) in ROC with sensitivity of 71.4% and, specificity of 75.6% in differentiating liver abscess and tumor. Combining with NIC in delay phase, the respectively values improved to 0.963, and 89.3% and 93.3%. Conclusion: The quantitative parameters in single source dual-energy CT provide high diagnostic accuracy in differentiating liver abscesses from liver metastases. … (more)
- Is Part Of:
- European journal of radiology. Issue 113(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 113(2019)
- Issue Display:
- Volume 113, Issue 113 (2019)
- Year:
- 2019
- Volume:
- 113
- Issue:
- 113
- Issue Sort Value:
- 2019-0113-0113-0000
- Page Start:
- 204
- Page End:
- 208
- Publication Date:
- 2019-04
- Subjects:
- NIC normalized iodine concentration -- Eff-Z effective atomic number -- AUC area under the curve -- MRI magnetic resonance imaging -- ROC receiver operating characteristic -- ROI region of interest -- GSI gemstone spectral imaging
Liver abscess -- Liver metastasis -- Differential diagnosis
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.02.024 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9739.xml