Evaluation of the sub-surface morphology and composition of gunshot residue using focussed ion beam analysis. (April 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of the sub-surface morphology and composition of gunshot residue using focussed ion beam analysis. (April 2019)
- Main Title:
- Evaluation of the sub-surface morphology and composition of gunshot residue using focussed ion beam analysis
- Authors:
- Lucas, Nick
Seyfang, Kelsey E.
Plummer, Andrew
Cook, Michael
Kirkbride, K. Paul
Kobus, Hilton - Abstract:
- Highlights: FIB was used to section GSR particles generated by different ammunitions. Sub-surface morphology appears to differ between ammunition. Distinct compositional features are observable in cross-section. Additional information may be obtained from GSR, at the sub-particle level. Abstract: Recent work in the forensic analysis of Gunshot residues (GSR) has suggested that the sub-surface or internal composition and morphology of these residues be explored. A particular area of interest is in heavy metal free, or non-toxic ammunition, which are becoming more frequently encountered in the marketplace. As the formulation of the primer compound changes the conditions of the firearm discharge, there is the possibility that different primer formulations may result in the formation of different GSR particles with distinct internal morphologies and compositions. To that end, the internal morphology and composition of GSR particles may provide additional information that could be useful in the investigation of firearms crime. This research investigated the internal morphology of GSR originating from a variety of different ammunition products. Both traditional three-component primed ammunition, and a selection of heavy metal free and non-toxic alternatives were considered. Particles were identified using SEM–EDS, before being cross-sectioned using a focussed ion beam (FIB) instrument. The FIB-sectioned particles were then re-acquired and mapped using SEM–EDS, to assess bothHighlights: FIB was used to section GSR particles generated by different ammunitions. Sub-surface morphology appears to differ between ammunition. Distinct compositional features are observable in cross-section. Additional information may be obtained from GSR, at the sub-particle level. Abstract: Recent work in the forensic analysis of Gunshot residues (GSR) has suggested that the sub-surface or internal composition and morphology of these residues be explored. A particular area of interest is in heavy metal free, or non-toxic ammunition, which are becoming more frequently encountered in the marketplace. As the formulation of the primer compound changes the conditions of the firearm discharge, there is the possibility that different primer formulations may result in the formation of different GSR particles with distinct internal morphologies and compositions. To that end, the internal morphology and composition of GSR particles may provide additional information that could be useful in the investigation of firearms crime. This research investigated the internal morphology of GSR originating from a variety of different ammunition products. Both traditional three-component primed ammunition, and a selection of heavy metal free and non-toxic alternatives were considered. Particles were identified using SEM–EDS, before being cross-sectioned using a focussed ion beam (FIB) instrument. The FIB-sectioned particles were then re-acquired and mapped using SEM–EDS, to assess both internal morphology and composition. Particles observed in this study presented distinct morphological and compositional features at the sub-particle level that may provide an indication of the primer formulation from which they originated. That said, further investigation of a variety of samples should be undertaken to verify the consistency of these features, or any deviations that may be observed based on primer type. However, these results indicate that there may be promise in obtaining additional detail from sub-particle morphology and composition. … (more)
- Is Part Of:
- Forensic science international. Volume 297(2019)
- Journal:
- Forensic science international
- Issue:
- Volume 297(2019)
- Issue Display:
- Volume 297, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 297
- Issue:
- 2019
- Issue Sort Value:
- 2019-0297-2019-0000
- Page Start:
- 100
- Page End:
- 110
- Publication Date:
- 2019-04
- Subjects:
- Forensic science -- Gunshot residue -- Focused ion beam -- Scanning electron microscopy
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2019.01.030 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9730.xml