A dual-purpose MRI acquisition to combine 4D-MRI and dynamic contrast-enhanced imaging for abdominal radiotherapy planning. (8th March 2019)
- Record Type:
- Journal Article
- Title:
- A dual-purpose MRI acquisition to combine 4D-MRI and dynamic contrast-enhanced imaging for abdominal radiotherapy planning. (8th March 2019)
- Main Title:
- A dual-purpose MRI acquisition to combine 4D-MRI and dynamic contrast-enhanced imaging for abdominal radiotherapy planning
- Authors:
- Stemkens, Bjorn
Prins, Fieke M
Bruijnen, Tom
Kerkmeijer, Linda G W
Lagendijk, Jan J W
van den Berg, Cornelis A T
Tijssen, Rob H N - Abstract:
- Abstract: For successful abdominal radiotherapy it is crucial to have a clear tumor definition and an accurate characterization of the motion. While dynamic contrast-enhanced (DCE) MRI aids tumor visualization, it is often hampered by motion artifacts. 4D-MRI characterizes this motion, but often lacks the contrast to clearly visualize the tumor. This dual requirement is challenging due to time constraints. Here, we propose combining both into a single acquisition by reconstructing the data in various ways in order to achieve both high spatio-temporal resolution DCE-MRI and accurate 4D-MRI motion estimates. A 5 min T1 -weigthed DCE acquisition was collected in five renal-cell carcinoma patients and simulated in a digital phantom. Data were acquired continuously using a 3D golden angle radial stack-of-stars acquisition. This enabled three types of reconstruction; (1) a high spatio-temporal resolution DCE time series, (2) a 5D reconstruction and (3) a contrast-enhanced 4D-MRI for motion characterization. Motion extracted from the 4D- and 5D-MRI was compared with a separately acquired 4D-MRI and additional 2D cine MR imaging. Simulations on XCAT showed that 5D reconstructions severely underestimated motion ( ), whereas contrast-enhanced 4D-MRI only underestimated motion by . This was confirmed in the in vivo data where motion of the contrast-enhanced 4D-MRI was approximately smaller than the motion in the 2D cine MRI (5.8 mm versus 6.5 mm), but equal to a separately acquiredAbstract: For successful abdominal radiotherapy it is crucial to have a clear tumor definition and an accurate characterization of the motion. While dynamic contrast-enhanced (DCE) MRI aids tumor visualization, it is often hampered by motion artifacts. 4D-MRI characterizes this motion, but often lacks the contrast to clearly visualize the tumor. This dual requirement is challenging due to time constraints. Here, we propose combining both into a single acquisition by reconstructing the data in various ways in order to achieve both high spatio-temporal resolution DCE-MRI and accurate 4D-MRI motion estimates. A 5 min T1 -weigthed DCE acquisition was collected in five renal-cell carcinoma patients and simulated in a digital phantom. Data were acquired continuously using a 3D golden angle radial stack-of-stars acquisition. This enabled three types of reconstruction; (1) a high spatio-temporal resolution DCE time series, (2) a 5D reconstruction and (3) a contrast-enhanced 4D-MRI for motion characterization. Motion extracted from the 4D- and 5D-MRI was compared with a separately acquired 4D-MRI and additional 2D cine MR imaging. Simulations on XCAT showed that 5D reconstructions severely underestimated motion ( ), whereas contrast-enhanced 4D-MRI only underestimated motion by . This was confirmed in the in vivo data where motion of the contrast-enhanced 4D-MRI was approximately smaller than the motion in the 2D cine MRI (5.8 mm versus 6.5 mm), but equal to a separately acquired 4D-MRI (5.8 mm versus 5.9 mm). 5D reconstructions underestimated the motion by more than, but minimized respiratory-induced blurring in the contrast enhanced images. DCE time-series demonstrated clear tumor visualization and contrast enhancement throughout the entire field-of-view. DCE- and 4D-MRI can be integrated into a single acquisition that enables different reconstructions with complementary information for abdominal radiotherapy planning and, in an MRI-guided treatment, precise motion information, input for motion models, and rapid feedback on the contrast enhancement. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 64:Number 6(2019:Mar.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 64:Number 6(2019:Mar.)
- Issue Display:
- Volume 64, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 6
- Issue Sort Value:
- 2019-0064-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03-08
- Subjects:
- dynamic contrast ehanced imaging -- 4D-MRI -- GRASP -- motion management -- MRI-guided radiotherapy -- renal cell carcinoma -- radiotherapy treatment planning
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ab0295 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9723.xml