Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry. (January 2019)
- Record Type:
- Journal Article
- Title:
- Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry. (January 2019)
- Main Title:
- Bicuspid Aortic Valve Anatomy and Relationship With Devices
- Authors:
- Tchetche, Didier
de Biase, Chiara
van Gils, Lennart
Parma, Radoslaw
Ochala, Andrzej
Lefevre, Thierry
Hovasse, Thomas
De Backer, Ole
Sondergaard, Lars
Bleiziffer, Sabine
Lange, Rudiger
Kornowski, Ran
Landes, Uri
Norgaard, Bjarne Linde
Biasco, Luigi
Philippart, Raphaël
Molina-Martin de Nicolas, Javier
Mylotte, Darren
Lemee, Caroline
Dumonteil, Nicolas
Van Mieghem, Nicolas M. - Abstract:
- Abstract : Background: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. Methods and Results: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P =0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P <0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P =0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P <0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. Conclusions: Second-generation prostheses similarlyAbstract : Background: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. Methods and Results: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P =0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P <0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P =0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P <0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. Conclusions: Second-generation prostheses similarly reshape the aortic annulus in TAV and BAV. Prostheses keep consistent diameters from distal edge to 12 mm in TAV and BAV. Prosthesis underexpansion is constantly observed in BAV. Annular-based sizing is accurate in BAV with minimal oversizing. The intercommissural distance, 4 mm above the annulus, could be integrated in gray zones. Clinical Trial Registration: URL:https://www.clinicaltrials.gov . Unique identifier: NCT03495050. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 12:Number 1(2019)
- Journal:
- Circulation
- Issue:
- Volume 12:Number 1(2019)
- Issue Display:
- Volume 12, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2019-0012-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- aortic valve -- bicuspid -- heart valve diseases -- multidetector computed tomography -- tricuspid valve
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.118.007107 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9716.xml