Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts. Issue 2 (March 2019)
- Record Type:
- Journal Article
- Title:
- Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts. Issue 2 (March 2019)
- Main Title:
- Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts
- Authors:
- Zhao, Jing
Luo, Dongqiang
Sun, Yong
Niu, Lingling
Zhao, Feng
Wang, Xiaoying
Wang, Hua
Chen, Qian
Zhou, Xingtao - Abstract:
- Purpose: To investigate the safety and efficacy of implanting a posterior chamber implantable collamer lens with a central hole in cases of high myopia with peripheral primary iris or ciliary body cysts. Methods: A total of 37 eyes of 19 patients with primary iris or ciliary body cysts detected by ultrasonic biological microscope were included, with spherical powers of −10.26 ± 3.28 D and cylinder powers of −1.71 ± 1.18 D. Each patient received ultrasonic biological microscope and a routine examination before implantation of the implantable collamer lens. A routine postoperative follow-up was performed to observe changes in the iris or ciliary body cyst, ranging from 3 to 18 months. Results: There were no complications. At the last follow-up, 56.8% (21/37) of eyes achieved the same corrected distance visual acuity as their preoperative measurements, 43.2% of eyes were enhanced by ≥1 line, and no patients' corrected distance visual acuity declined. The efficacy index and safety index were 0.95 and 1.11, respectively. After 18 months, 66.7% of the spherical equivalents were between ±0.5 D with 100% between ±1.0 D. The postoperative mean spherical equivalents at 1, 3, 6, 12, and 18 months were −0.45 ± 0.31 D, −0.39 ± 0.29 D, −0.36 ± 0.30 D, −0.39 ± 0.38 D, and −0.48 ± 0.23 D (p = 0.789). The vaults were 516 ± 140, 548 ± 124, 498 ± 133, 582 ± 161, and 557 ± 110 μm (p = 0.355). There were no changes in size (p > 0.05), number, or position of the iris or ciliary body cysts.Purpose: To investigate the safety and efficacy of implanting a posterior chamber implantable collamer lens with a central hole in cases of high myopia with peripheral primary iris or ciliary body cysts. Methods: A total of 37 eyes of 19 patients with primary iris or ciliary body cysts detected by ultrasonic biological microscope were included, with spherical powers of −10.26 ± 3.28 D and cylinder powers of −1.71 ± 1.18 D. Each patient received ultrasonic biological microscope and a routine examination before implantation of the implantable collamer lens. A routine postoperative follow-up was performed to observe changes in the iris or ciliary body cyst, ranging from 3 to 18 months. Results: There were no complications. At the last follow-up, 56.8% (21/37) of eyes achieved the same corrected distance visual acuity as their preoperative measurements, 43.2% of eyes were enhanced by ≥1 line, and no patients' corrected distance visual acuity declined. The efficacy index and safety index were 0.95 and 1.11, respectively. After 18 months, 66.7% of the spherical equivalents were between ±0.5 D with 100% between ±1.0 D. The postoperative mean spherical equivalents at 1, 3, 6, 12, and 18 months were −0.45 ± 0.31 D, −0.39 ± 0.29 D, −0.36 ± 0.30 D, −0.39 ± 0.38 D, and −0.48 ± 0.23 D (p = 0.789). The vaults were 516 ± 140, 548 ± 124, 498 ± 133, 582 ± 161, and 557 ± 110 μm (p = 0.355). There were no changes in size (p > 0.05), number, or position of the iris or ciliary body cysts. Conclusion: Implantable collamer lens implantation is safe and effective for highly myopic patients with peripheral primary iris and ciliary body cysts. The cysts did not change after operation in this study. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 29:Issue 2(2019)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 29:Issue 2(2019)
- Issue Display:
- Volume 29, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2019-0029-0002-0000
- Page Start:
- 171
- Page End:
- 177
- Publication Date:
- 2019-03
- Subjects:
- Implantable collamer lens -- primary iris and ciliary body cyst -- ultrasonic biological microscope -- safety
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/1120672118766445 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9704.xml