3154 Resolution of right atrial congestion before LVAD implantation is associated with improved outcomes. (27th March 2019)
- Record Type:
- Journal Article
- Title:
- 3154 Resolution of right atrial congestion before LVAD implantation is associated with improved outcomes. (27th March 2019)
- Main Title:
- 3154 Resolution of right atrial congestion before LVAD implantation is associated with improved outcomes
- Authors:
- Gulati, Gaurav
Sutaria, Nilay
Vest, Amanda
DeNofrio, David
Kawabori, Masashi
Couper, Gregory
Kiernan, Michael - Abstract:
- Abstract : OBJECTIVES/SPECIFIC AIMS: Increased right atrial pressure is known to be a predictor of poor outcomes after LVAD implantation. Whether resolution of right heart congestion prior to LVAD implantation is associated with more favorable outcomes is not well understood. METHODS/STUDY POPULATION: We analyzed LVAD recipients from our institution from 1/1/2015 to 2/28/2018. We excluded patients bridged to LVAD with ECMO support. Patients with admission right atrial pressure (RAPadmit) and implant RAP (RAPimplant) ≥ 14 mmHg were defined as having persistent congestion, while patients with RAPadmit ≥ 14 mmHg and RAPimplant < 14 mmHg were defined as having resolved congestion. Baseline characteristics between groups were compared using the Chi-square and unpaired t-tests. Time to death or RVAD was compared between groups using Cox proportional hazards models. RESULTS/ANTICIPATED RESULTS: Of 57 LVAD recipients with RAPadmit ≥ 14 mmHg, 14 (25%) had persistent congestion at the time of LVAD implantation. While there were no statistically significant differences between groups, patients with persistent congestion were more likely to be INTERMACS profile 1 (21.4% vs 9.5%), less likely to have a destination therapy device strategy (28.6% vs 34.9%), less likely to have moderate or severe right ventricular (RV) dysfunction (64.3% vs 83.7%), and had similar RAPadmit (20.4 mmHg vs 18.9 mmHg) compared to patients with resolved congestion. Median follow up was 307 days. Patients withAbstract : OBJECTIVES/SPECIFIC AIMS: Increased right atrial pressure is known to be a predictor of poor outcomes after LVAD implantation. Whether resolution of right heart congestion prior to LVAD implantation is associated with more favorable outcomes is not well understood. METHODS/STUDY POPULATION: We analyzed LVAD recipients from our institution from 1/1/2015 to 2/28/2018. We excluded patients bridged to LVAD with ECMO support. Patients with admission right atrial pressure (RAPadmit) and implant RAP (RAPimplant) ≥ 14 mmHg were defined as having persistent congestion, while patients with RAPadmit ≥ 14 mmHg and RAPimplant < 14 mmHg were defined as having resolved congestion. Baseline characteristics between groups were compared using the Chi-square and unpaired t-tests. Time to death or RVAD was compared between groups using Cox proportional hazards models. RESULTS/ANTICIPATED RESULTS: Of 57 LVAD recipients with RAPadmit ≥ 14 mmHg, 14 (25%) had persistent congestion at the time of LVAD implantation. While there were no statistically significant differences between groups, patients with persistent congestion were more likely to be INTERMACS profile 1 (21.4% vs 9.5%), less likely to have a destination therapy device strategy (28.6% vs 34.9%), less likely to have moderate or severe right ventricular (RV) dysfunction (64.3% vs 83.7%), and had similar RAPadmit (20.4 mmHg vs 18.9 mmHg) compared to patients with resolved congestion. Median follow up was 307 days. Patients with persistent congestion had a higher frequency of death or RVAD implantation compared to those with resolved congestion (50% vs 14%, HR 3.75, 95% CI 1.25–11.25, p=0.02). DISCUSSION/SIGNIFICANCE OF IMPACT: Among patients with elevated RAP at admission, patients with persistently elevated RAP at the time of LVAD implantation had worse outcomes than patients who were able to be decongested prior to surgery. These data support optimization of RV filling pressures prior to LVAD surgery. … (more)
- Is Part Of:
- Journal of clinical and translational science. Volume 3(2019)Supplement 1
- Journal:
- Journal of clinical and translational science
- Issue:
- Volume 3(2019)Supplement 1
- Issue Display:
- Volume 3, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2019-0003-0001-0000
- Page Start:
- 53
- Page End:
- 53
- Publication Date:
- 2019-03-27
- Subjects:
- Clinical medicine -- Research -- Periodicals
Medicine, Experimental -- Periodicals
Human experimentation in medicine -- Periodicals
616.027 - Journal URLs:
- https://www.cambridge.org/core/journals/journal-of-clinical-and-translational-science ↗
- DOI:
- 10.1017/cts.2019.126 ↗
- Languages:
- English
- ISSNs:
- 2059-8661
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 9700.xml