Determination of urea concentration using urease-containing polyelectrolyte microcapsules. Issue 12 (18th February 2019)
- Record Type:
- Journal Article
- Title:
- Determination of urea concentration using urease-containing polyelectrolyte microcapsules. Issue 12 (18th February 2019)
- Main Title:
- Determination of urea concentration using urease-containing polyelectrolyte microcapsules
- Authors:
- Kim, Aleksandr L.
Musin, Egor V.
Dubrovskii, Alexey V.
Tikhonenko, Sergey A. - Abstract:
- Abstract : A diagnostic system of multiple use for urea based on polyelectrolyte microcapsules. Abstract : Nowadays, the enzymological method used in clinical diagnostics has several problems: a short lifetime of the enzyme sensor in solution, its susceptibility in the presence of proteolytic enzymes, and the impossibility of multiple uses. We proposed the modification of the standard method of urea detection, which will solve the problems mentioned above. The main idea of the proposed approach was encapsulation of urease into microcapsules obtained by the method of alternate adsorption of oppositely charged polyelectrolytes. The determination was conducted with the help of unfixed (microdiagnosticum) and fixed microcapsules on a solid surface (diagnostic plate). Multiple uses of microdiagnosticum and diagnostic plate have been shown. The results obtained exhibited deviations and did not exceed the value of 9.6%. We determined the urea concentration in the serum blood by the standard Berthelot method using a diagnostic plate and a microdiagnosticum for detection in the urine. The results obtained differed from the results obtained using a free enzyme by no more than 4.26% for diagnostic plates and 1.67% for microdiagnosticum. The diagnostic plate exhibited detectable concentrations in the range of 5–50 mmol L −1 and linearity up to 40 mmol L −1 ; moreover, deviation from linearity did not exceed 10%, and the coefficient of variation did not exceed 7.17. MicrodiagnosticumAbstract : A diagnostic system of multiple use for urea based on polyelectrolyte microcapsules. Abstract : Nowadays, the enzymological method used in clinical diagnostics has several problems: a short lifetime of the enzyme sensor in solution, its susceptibility in the presence of proteolytic enzymes, and the impossibility of multiple uses. We proposed the modification of the standard method of urea detection, which will solve the problems mentioned above. The main idea of the proposed approach was encapsulation of urease into microcapsules obtained by the method of alternate adsorption of oppositely charged polyelectrolytes. The determination was conducted with the help of unfixed (microdiagnosticum) and fixed microcapsules on a solid surface (diagnostic plate). Multiple uses of microdiagnosticum and diagnostic plate have been shown. The results obtained exhibited deviations and did not exceed the value of 9.6%. We determined the urea concentration in the serum blood by the standard Berthelot method using a diagnostic plate and a microdiagnosticum for detection in the urine. The results obtained differed from the results obtained using a free enzyme by no more than 4.26% for diagnostic plates and 1.67% for microdiagnosticum. The diagnostic plate exhibited detectable concentrations in the range of 5–50 mmol L −1 and linearity up to 40 mmol L −1 ; moreover, deviation from linearity did not exceed 10%, and the coefficient of variation did not exceed 7.17. Microdiagnosticum exhibited detectable concentrations in the range of 5–55 mmol L −1 and linearity up to 50 mmol L −1 ; also, deviation from linearity did not exceed 7%, and the coefficient of variation did not exceed 2.85. … (more)
- Is Part Of:
- Analytical methods. Volume 11:Issue 12(2019)
- Journal:
- Analytical methods
- Issue:
- Volume 11:Issue 12(2019)
- Issue Display:
- Volume 11, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 12
- Issue Sort Value:
- 2019-0011-0012-0000
- Page Start:
- 1585
- Page End:
- 1590
- Publication Date:
- 2019-02-18
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay02481b ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9681.xml