Radiotherapy quality assurance of SBRT for patients with centrally located lung tumours within the multicentre phase II EORTC Lungtech trial: Benchmark case results. (March 2019)
- Record Type:
- Journal Article
- Title:
- Radiotherapy quality assurance of SBRT for patients with centrally located lung tumours within the multicentre phase II EORTC Lungtech trial: Benchmark case results. (March 2019)
- Main Title:
- Radiotherapy quality assurance of SBRT for patients with centrally located lung tumours within the multicentre phase II EORTC Lungtech trial: Benchmark case results
- Authors:
- Lambrecht, Marie
Clementel, Enrico
Sonke, Jan-Jacob
Nestle, Ursula
Adebahr, Sonja
Guckenberger, Mathias
Andratschke, Nicolaus
Weber, Damien C.
Verheij, Marcel
Hurkmans, Coen W. - Abstract:
- Highlights: Radiotherapy quality assurance procedures improve dose coverage significantly. Delineation variation have a larger influence on PTV coverage than variations in planning and irradiation techniques. Results suggest that dose tolerance criteria should preferably take into account the accuracy of delineation. Abstract: Purpose: To report on the benchmark case (BC) study performed in the context of the European Organisation for Research and Treatment of Cancer prospective multicentre Lungtech trial of SBRT for patients with inoperable centrally located lung tumours. Methods and materials: Target volume and organs at risk (OARs) delineations first needed to be acceptable before the treatment plan was reviewed. Retrospectively, Dice similarity coefficients of the OARs and the target volumes were calculated and a set of gold standard contours adapted for each institution margins was applied on the accepted dose submissions to evaluate the influence of acceptable delineation variations on dosimetry. Results: Twenty-five institutions participated. Five BCs were accepted at the first attempt. Twenty institutions had to revise their delineation at least once and seven had to revise their planning once. The V60 Gy dose coverage improved significantly ( p = 0.05) between the first and final submissions from median (range) 94.8% (22.5–97.8) to 95.3% (70.5–99.3). The median Dice coefficient varied significantly between OARs: The lowest values were found for the brachial plexusHighlights: Radiotherapy quality assurance procedures improve dose coverage significantly. Delineation variation have a larger influence on PTV coverage than variations in planning and irradiation techniques. Results suggest that dose tolerance criteria should preferably take into account the accuracy of delineation. Abstract: Purpose: To report on the benchmark case (BC) study performed in the context of the European Organisation for Research and Treatment of Cancer prospective multicentre Lungtech trial of SBRT for patients with inoperable centrally located lung tumours. Methods and materials: Target volume and organs at risk (OARs) delineations first needed to be acceptable before the treatment plan was reviewed. Retrospectively, Dice similarity coefficients of the OARs and the target volumes were calculated and a set of gold standard contours adapted for each institution margins was applied on the accepted dose submissions to evaluate the influence of acceptable delineation variations on dosimetry. Results: Twenty-five institutions participated. Five BCs were accepted at the first attempt. Twenty institutions had to revise their delineation at least once and seven had to revise their planning once. The V60 Gy dose coverage improved significantly ( p = 0.05) between the first and final submissions from median (range) 94.8% (22.5–97.8) to 95.3% (70.5–99.3). The median Dice coefficient varied significantly between OARs: The lowest values were found for the brachial plexus 0.25 (0.01–0.54) and the highest for the spinal cord 0.89 (0.71–0.95). The mean PTV Dice coefficient was 0.82 (0.48–0.92). Applying the gold standard contours, only one institution remained compliant with the dose coverage criteria with V60 Gy median (range) of 83.4% (54.2–93.9). Conclusions: Clinical guidelines and radiotherapy protocols are not a substitute for timely radiotherapy quality assurance procedures, which improve dose coverage significantly. Delineation remains the main source of BC rejection and plan review without first reviewing delineation may not be efficient. Our results show that delineation variations seem to have a larger influence on PTV coverage than variations in planning and irradiation techniques and thus suggest that dose tolerance criteria should preferably take into account the accuracy of delineation. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 132(2019)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 132(2019)
- Issue Display:
- Volume 132, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 132
- Issue:
- 2019
- Issue Sort Value:
- 2019-0132-2019-0000
- Page Start:
- 63
- Page End:
- 69
- Publication Date:
- 2019-03
- Subjects:
- Benchmark -- SBRT -- Lung -- Planning exercise -- Clinical trial
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2018.10.025 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9655.xml