Measurement of the absolute number of photons of the hard X‐ray beamline at the Linac Coherent Light Source. (11th February 2019)
- Record Type:
- Journal Article
- Title:
- Measurement of the absolute number of photons of the hard X‐ray beamline at the Linac Coherent Light Source. (11th February 2019)
- Main Title:
- Measurement of the absolute number of photons of the hard X‐ray beamline at the Linac Coherent Light Source
- Authors:
- Song, Sanghoon
Alonso-Mori, Roberto
Chollet, Matthieu
Feng, Yiping
Glownia, James M.
Lemke, Henrik T.
Sikorski, Marcin
Zhu, Diling
Moeller, Stefan
Lee, Hae Ja
Hunter, Mark S.
Carini, Gabriella
Tiedtke, Kai
Jastrow, Ulf
Sorokin, Andrey
Richter, Mathias
Owada, Shigeki
Tono, Kensuke
Saito, Norio
Tanaka, Takahiro
Kato, Masahiro
Yabashi, Makina
Robert, Aymeric - Abstract:
- Abstract : Measurement of the absolute number of photons per pulse as a function of X‐ray photon energy at the hard X‐ray beamline of LCLS is presented. It is estimated by two different detectors and is used to characterize the hard X‐ray beamline optics transmission as well as the third‐harmonic content of the LCLS radiation. Abstract : X‐ray free‐electron lasers provide intense pulses of coherent X‐rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X‐ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X‐ray beamline to specifically monitor the intensity of individual X‐ray pulses. To date, these can however only provide a single‐shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X‐ray regime at LCLS which is typically 3.5 × 10 11 photons shot −1 between 6 and 9.5 keV at the X‐ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X‐ray beamline over this energy range is measured and the third‐harmonic content of ≈0.47% below 9 keV is characterized.
- Is Part Of:
- Journal of synchrotron radiation. Volume 26:Part 2(2019)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 26:Part 2(2019)
- Issue Display:
- Volume 26, Issue 2, Part 2 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 2
- Part:
- 2
- Issue Sort Value:
- 2019-0026-0002-0002
- Page Start:
- 320
- Page End:
- 327
- Publication Date:
- 2019-02-11
- Subjects:
- FEL -- hard X‐rays -- absolute intensity
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S1600577519000250 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9647.xml