Characterizing a novel scintillating glass for application to megavoltage cone‐beam computed tomography. Issue 3 (14th February 2019)
- Record Type:
- Journal Article
- Title:
- Characterizing a novel scintillating glass for application to megavoltage cone‐beam computed tomography. Issue 3 (14th February 2019)
- Main Title:
- Characterizing a novel scintillating glass for application to megavoltage cone‐beam computed tomography
- Authors:
- Hu, Yue‐Houng
Shedlock, Daniel
Wang, Adam
Rottmann, Joerg
Baturin, Paul
Myronakis, Marios
Huber, Pascal
Fueglistaller, Rony
Shi, Mengying
Morf, Daniel
Star‐Lack, Josh
Berbeco, Ross I. - Abstract:
- Abstract : Purpose: The purpose of this study was to evaluate the performance of a prototype electric portal imaging device (EPID) with a high detective quantum efficiency (DQE) scintillator, LKH‐5. Specifically, image quality in context of both planar and megavoltage (MV) cone‐beam computed tomography (CBCT) is analyzed. Methods: Planar image quality in terms of modulation transfer function (MTF), noise power spectrum (NPS), and DQE are measured and compared to an existing EPID (AS‐1200) using the 6 MV beamline for a Varian TrueBeam linac. Imager performance is contextualized for three‐dimensional (3D), MV‐CBCT performance by measuring imager lag and analyzing the expected degradation of the DQE as a function of dose. Finally, comparisons between reconstructed images of the Catphan phantom in terms of qualitative quality and signal‐difference‐to‐noise ratio (SDNR) are made for 6 MV images using both conventional and LKH‐5 EPIDs as well as for the kilovoltage (kV) on‐board imager (OBI). Results: Analysis of the NPS reveals linearity at all measured doses using the prototype LKH‐5 detector. While the first zero of the MTF is much lower for the LKH‐5 detector than the conventional EPID (0.6 cycles/mm vs 1.6 cycles/mm), the normalized NPS (NNPS) multiplied by total quanta (qNNPS) of the LKH‐5 detector is roughly a factor of seven to eight times lower, yielding a DQE(0) of approximately 8%. First, second, and third frame lag were measured at approximately 23%, 5%, and 1%,Abstract : Purpose: The purpose of this study was to evaluate the performance of a prototype electric portal imaging device (EPID) with a high detective quantum efficiency (DQE) scintillator, LKH‐5. Specifically, image quality in context of both planar and megavoltage (MV) cone‐beam computed tomography (CBCT) is analyzed. Methods: Planar image quality in terms of modulation transfer function (MTF), noise power spectrum (NPS), and DQE are measured and compared to an existing EPID (AS‐1200) using the 6 MV beamline for a Varian TrueBeam linac. Imager performance is contextualized for three‐dimensional (3D), MV‐CBCT performance by measuring imager lag and analyzing the expected degradation of the DQE as a function of dose. Finally, comparisons between reconstructed images of the Catphan phantom in terms of qualitative quality and signal‐difference‐to‐noise ratio (SDNR) are made for 6 MV images using both conventional and LKH‐5 EPIDs as well as for the kilovoltage (kV) on‐board imager (OBI). Results: Analysis of the NPS reveals linearity at all measured doses using the prototype LKH‐5 detector. While the first zero of the MTF is much lower for the LKH‐5 detector than the conventional EPID (0.6 cycles/mm vs 1.6 cycles/mm), the normalized NPS (NNPS) multiplied by total quanta (qNNPS) of the LKH‐5 detector is roughly a factor of seven to eight times lower, yielding a DQE(0) of approximately 8%. First, second, and third frame lag were measured at approximately 23%, 5%, and 1%, respectively, although no noticeable image artifacts were apparent in reconstructed volumes. Analysis of low‐dose performance reveals that DQE(0) remains at 80% of its maximum value at a dose as low as 7.5 × 10 −6 MU. For a 400 projection technique, this represents a total scan dose of 0.0030 MU, suggesting that if imaging doses are increased to a value typical of kV‐CBCT scans (~2.7 cGy), the LKH‐5 detector will retain quantum noise limited performance. Finally, comparing Catphan scans, the prototype detector exhibits much lower image noise than the conventional EPID, resulting in improved small object representation. Furthermore, SDNR of H2 O and polystyrene cylinders improved from −1.95 and 2.94 to −15 and 18.7, respectively. Conclusions: Imaging performance of the prototype LKH‐5 detector was measured and analyzed for both planar and 3D contexts. Improving noise transfer of the detector results in concurrent improvement of DQE(0). For 3D imaging, temporal characteristics were adequate for artifact‐free performance and at relevant doses, the detector retained quantum noise limited performance. Although quantitative MTF measurements suggest poorer resolution, small object representation of the prototype imager is qualitatively improved over the conventional detector due to the measured reduction in noise. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 3(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 3(2019)
- Issue Display:
- Volume 46, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 3
- Issue Sort Value:
- 2019-0046-0003-0000
- Page Start:
- 1323
- Page End:
- 1330
- Publication Date:
- 2019-02-14
- Subjects:
- DQE -- EPID -- MTF -- MV‐CBCT -- NPS -- portal imaging -- scintillator
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13355 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9645.xml