Reliability of low‐flow vasoreactivity in the brachial artery of adolescents. Issue 3 (25th November 2018)
- Record Type:
- Journal Article
- Title:
- Reliability of low‐flow vasoreactivity in the brachial artery of adolescents. Issue 3 (25th November 2018)
- Main Title:
- Reliability of low‐flow vasoreactivity in the brachial artery of adolescents
- Authors:
- Kranen, Sascha H.
Bond, Bert
Williams, Craig A.
Barker, Alan R. - Abstract:
- Abstract: Purpose: Macrovascular endothelial function is commonly assessed using flow‐mediated dilation (FMD) and is nitric oxide (NO) dependent. However, the vasoreactivity to low flow during the FMD protocol may complement FMD interpretation. This study aimed to investigate in adolescents: (1) the day‐to‐day reliability of low‐flow‐mediated constriction (L‐FMC) and composite vessel reactivity (CVR); and (2) the relationship between L‐FMC and FMD. Methods: A retrospective analysis of data on 27 adolescents (14.3 ± 0.6 year, 12 males) was performed. Participants had two repeat measures, on separate days, of macrovascular function using high‐resolution ultrasound for assessment of L‐FMC, FMD, and CVR. Results: On average, the L‐FMC response was vasoconstriction on both days (−0.59 ± 2.22% and −0.16 ± 1.50%, respectively). In contrast, an inconsistent response to low flow (vasoconstriction, dilation, or no change) was observed on an individual level. Cohen's Kappa revealed poor agreement for classifying the L‐FMC measurement between visits ( k = 0.04, P > .05). Assessment of the actual vessel diameter was robust with a coefficient of variation of 1.7% (baseline and peak) and 2.7% (low‐flow). The between‐day correlation coefficient between measures was r = .18, r = .96 and r = .52 for L‐FMC, FMD, and CVR, respectively. No significant correlation between FMD and L‐FMC was observed for either visit ( r = −.06 and r = −.07, respectively; P > .05). Conclusion: InAbstract: Purpose: Macrovascular endothelial function is commonly assessed using flow‐mediated dilation (FMD) and is nitric oxide (NO) dependent. However, the vasoreactivity to low flow during the FMD protocol may complement FMD interpretation. This study aimed to investigate in adolescents: (1) the day‐to‐day reliability of low‐flow‐mediated constriction (L‐FMC) and composite vessel reactivity (CVR); and (2) the relationship between L‐FMC and FMD. Methods: A retrospective analysis of data on 27 adolescents (14.3 ± 0.6 year, 12 males) was performed. Participants had two repeat measures, on separate days, of macrovascular function using high‐resolution ultrasound for assessment of L‐FMC, FMD, and CVR. Results: On average, the L‐FMC response was vasoconstriction on both days (−0.59 ± 2.22% and −0.16 ± 1.50%, respectively). In contrast, an inconsistent response to low flow (vasoconstriction, dilation, or no change) was observed on an individual level. Cohen's Kappa revealed poor agreement for classifying the L‐FMC measurement between visits ( k = 0.04, P > .05). Assessment of the actual vessel diameter was robust with a coefficient of variation of 1.7% (baseline and peak) and 2.7% (low‐flow). The between‐day correlation coefficient between measures was r = .18, r = .96 and r = .52 for L‐FMC, FMD, and CVR, respectively. No significant correlation between FMD and L‐FMC was observed for either visit ( r = −.06 and r = −.07, respectively; P > .05). Conclusion: In adolescents, the low‐flow vasoreactivity is inconsistent between days. Whereas the actual vessel diameter is reproducible, the measurement of L‐FMC and CVR has poor between‐day reliability compared to FMD. Finally, L‐FMC, and FMD are not significantly correlated. … (more)
- Is Part Of:
- Journal of clinical ultrasound. Volume 47:Issue 3(2019)
- Journal:
- Journal of clinical ultrasound
- Issue:
- Volume 47:Issue 3(2019)
- Issue Display:
- Volume 47, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2019-0047-0003-0000
- Page Start:
- 133
- Page End:
- 138
- Publication Date:
- 2018-11-25
- Subjects:
- FMD -- L‐FMC -- low‐flow‐mediated constriction -- repeatability -- vascular function
Ultrasonics in medicine -- Periodicals
616.07543 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcu.22664 ↗
- Languages:
- English
- ISSNs:
- 0091-2751
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.791000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9646.xml