- Comparison of posturographic outcomes between two different devices
- Authors:
- Reinhardt, Lars
Heilmann, Florian
Teicher, Mirjam
Lauenroth, Andreas
Delank, Karl-Stefan
Schwesig, René
Wollny, Rainer
Kurz, Eduard - Abstract:
- Abstract: The Interactive Balance System (IBS), a posturography device for assessing posture control, is widely used in clinical and rehabilitation settings. However, data on the validity of the device are unavailable. Fluctuations of the center of pressure (COP) were measured in 24 healthy participants (age: 29 ± 5 (mean ± SD) years, 12 females) synchronously using the IBS, which was rigidly mounted on a Kistler platform. Four different bipedal conditions were examined: eyes open or closed on stable or soft surfaces. Time series were compared using congruity ( CON, proportion of the measurement time during which values of both devices changed similarly in direction), whereas IBS-specific postural outcomes were correlated with traditional postural control outcomes of the Kistler force platform. The time-displacement curves showed similar shapes for CON (>0.9) for each of the four standing conditions without differences between male and female participants ( P > 0.39). The path length results of both devices showed very high linear associations, explaining on average 92% (medio-lateral) or 96% (anterior-posterior) of the common variance. The Kistler path length of the anterior-posterior direction revealed nearly perfect linear associations with the stability index of the IBS ( r 2 > 0.99). The results of this study indicate that the IBS provides valid posturographic results. Since the medial-lateral and anterior-posterior trajectories of the IBS can be used to calculate COPAbstract: The Interactive Balance System (IBS), a posturography device for assessing posture control, is widely used in clinical and rehabilitation settings. However, data on the validity of the device are unavailable. Fluctuations of the center of pressure (COP) were measured in 24 healthy participants (age: 29 ± 5 (mean ± SD) years, 12 females) synchronously using the IBS, which was rigidly mounted on a Kistler platform. Four different bipedal conditions were examined: eyes open or closed on stable or soft surfaces. Time series were compared using congruity ( CON, proportion of the measurement time during which values of both devices changed similarly in direction), whereas IBS-specific postural outcomes were correlated with traditional postural control outcomes of the Kistler force platform. The time-displacement curves showed similar shapes for CON (>0.9) for each of the four standing conditions without differences between male and female participants ( P > 0.39). The path length results of both devices showed very high linear associations, explaining on average 92% (medio-lateral) or 96% (anterior-posterior) of the common variance. The Kistler path length of the anterior-posterior direction revealed nearly perfect linear associations with the stability index of the IBS ( r 2 > 0.99). The results of this study indicate that the IBS provides valid posturographic results. Since the medial-lateral and anterior-posterior trajectories of the IBS can be used to calculate COP fluctuations, comparisons between different measurement systems are possible. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 86(2019)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 86(2019)
- Issue Display:
- Volume 86, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 86
- Issue:
- 2019
- Issue Sort Value:
- 2019-0086-2019-0000
- Page Start:
- 218
- Page End:
- 224
- Publication Date:
- 2019-03-27
- Subjects:
- Postural control -- Force plate -- Upright standing -- Balance -- Concurrent validity
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2019.02.013 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9642.xml