Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans. Issue 1 (22nd August 2017)
- Record Type:
- Journal Article
- Title:
- Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans. Issue 1 (22nd August 2017)
- Main Title:
- Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
- Authors:
- Maraghechi, Borna
Davis, Jack
Badu, Shyam
Fleck, Andre
Darko, Johnson
Osei, Ernest - Abstract:
- Abstract: Background: Electronic portal imaging device (EPID) offers high-resolution digital image that can be compared with a predicted portal dose image. A very common method to quantitatively compare a measured and calculated dose distribution that is routinely used for quality assurance (QA) of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy treatment plans is the evaluation of the gamma index. The purpose of this work was to evaluate the gamma passing rate (%GP), maximum gamma ( γ max ), average gamma ( γ ave ), maximum dose difference (DDmax ) and the average dose difference (DDave ) for various regions of interest using Varian's implementation of three absolute dose gamma calculation techniques of improved, local, and combined improved and local. Methods and materials: We analyzed 232 portal dose images from 100 prostate cancer patients' VMAT plans obtained using the Varian EPID on TrueBeam Linacs. Results: Our data show that the %GP, γ max and γ ave depend on the gamma calculation method and the acceptance criteria. Higher %GP values were obtained compared with both our current institutional action level and the American Association of Physicists in Medicine Task Group 119 recommendations. Conclusions: The results of this study can be used to establish stricter action levels for pre-treatment QA of prostate VMAT plans. A stricter 3%/3 mm improved gamma criterion with a passing rate of 97% or the 2%/2 mm improved gamma criterion withAbstract: Background: Electronic portal imaging device (EPID) offers high-resolution digital image that can be compared with a predicted portal dose image. A very common method to quantitatively compare a measured and calculated dose distribution that is routinely used for quality assurance (QA) of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy treatment plans is the evaluation of the gamma index. The purpose of this work was to evaluate the gamma passing rate (%GP), maximum gamma ( γ max ), average gamma ( γ ave ), maximum dose difference (DDmax ) and the average dose difference (DDave ) for various regions of interest using Varian's implementation of three absolute dose gamma calculation techniques of improved, local, and combined improved and local. Methods and materials: We analyzed 232 portal dose images from 100 prostate cancer patients' VMAT plans obtained using the Varian EPID on TrueBeam Linacs. Results: Our data show that the %GP, γ max and γ ave depend on the gamma calculation method and the acceptance criteria. Higher %GP values were obtained compared with both our current institutional action level and the American Association of Physicists in Medicine Task Group 119 recommendations. Conclusions: The results of this study can be used to establish stricter action levels for pre-treatment QA of prostate VMAT plans. A stricter 3%/3 mm improved gamma criterion with a passing rate of 97% or the 2%/2 mm improved gamma criterion with a passing rate of 95% can be achieved without additional measurements or configurations. … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 17:Issue 1(2018)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 17:Issue 1(2018)
- Issue Display:
- Volume 17, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2018-0017-0001-0000
- Page Start:
- 44
- Page End:
- 52
- Publication Date:
- 2017-08-22
- Subjects:
- EPID, -- gamma index, -- portal dosimetry, -- VMAT quality assurance
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396917000486 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 9632.xml