3D beam–column corner joints retrofitted with X-shaped FRP sheets attached via the EBROG technique. (15th March 2019)
- Record Type:
- Journal Article
- Title:
- 3D beam–column corner joints retrofitted with X-shaped FRP sheets attached via the EBROG technique. (15th March 2019)
- Main Title:
- 3D beam–column corner joints retrofitted with X-shaped FRP sheets attached via the EBROG technique
- Authors:
- Mostofinejad, Davood
Hajrasouliha, Mohammadjavad - Abstract:
- Highlights: Six half-scale 3D RC beam-column joint specimens were retrofitted with FRP sheets. X-shaped FRP sheets were used with the EBROG technique. The proposed strengthening pattern prevented the joint shear failure. The plastic hinge was relocated away from the column interface into the beam. Abstract: Beam-column joints are fundamental structural components of a stable structure. Corner joints are more likely to fail due to their small size and inferior confinement. This calls for three-dimensional (3D) strengthening of corner joints with fiber reinforced polymer (FRP) sheets to improve the load carrying capacity and ductility of beam–column connections. The present study investigates the shear strength of non-seismic 3D corner joints lacking adequate transverse reinforcement in their joint panel but strengthened with carbon fiber reinforced polymer (CFRP) sheets. The externally bonded reinforcement on groove (EBROG) technique is used in the joints to delay the debonding of CFRP sheets off the concrete substrate. Maximum expected moment resistance of a beam/connection is typically obtained at the column interface. This, therefore, requires sufficient bonding strength provisioned between the FRP sheet and the concrete substrate over an acceptable range of the bonding length. Practical limitations, however, do not allow for enough length of the column interface to be strengthened. A new anchorage system of FRP fans is, therefore, provisioned to attain the requiredHighlights: Six half-scale 3D RC beam-column joint specimens were retrofitted with FRP sheets. X-shaped FRP sheets were used with the EBROG technique. The proposed strengthening pattern prevented the joint shear failure. The plastic hinge was relocated away from the column interface into the beam. Abstract: Beam-column joints are fundamental structural components of a stable structure. Corner joints are more likely to fail due to their small size and inferior confinement. This calls for three-dimensional (3D) strengthening of corner joints with fiber reinforced polymer (FRP) sheets to improve the load carrying capacity and ductility of beam–column connections. The present study investigates the shear strength of non-seismic 3D corner joints lacking adequate transverse reinforcement in their joint panel but strengthened with carbon fiber reinforced polymer (CFRP) sheets. The externally bonded reinforcement on groove (EBROG) technique is used in the joints to delay the debonding of CFRP sheets off the concrete substrate. Maximum expected moment resistance of a beam/connection is typically obtained at the column interface. This, therefore, requires sufficient bonding strength provisioned between the FRP sheet and the concrete substrate over an acceptable range of the bonding length. Practical limitations, however, do not allow for enough length of the column interface to be strengthened. A new anchorage system of FRP fans is, therefore, provisioned to attain the required bonding strength. The results are verified by studying the hysteretic response of the 3D corner joints strengthened via the proposed EBROG method and with the provisioned FRP fans. For this purpose, six half-scale 3D joint specimens were constructed and subjected to relevant tests. The specimens included a control, one reference specimen that satisfied the current building codes, and four FRP-retrofitted specimens with X-shaped strengthening patterns. The results revealed that the proposed strengthening pattern prevented joint shear failure. Furthermore, the proposed EBROG technique outperformed the externally bonded reinforcement (EBR) techniques as evidenced by the higher values of maximum load-carrying capacity and ductility recorded by the joint while CFRP debonding off the concrete substrate was also delayed. Maximum loading led to a drift ratio of 4.5%, indicating that application of the EBROG technique combined with FRP fans inhibited load reductions throughout the test period. … (more)
- Is Part Of:
- Engineering structures. Volume 183(2019)
- Journal:
- Engineering structures
- Issue:
- Volume 183(2019)
- Issue Display:
- Volume 183, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 183
- Issue:
- 2019
- Issue Sort Value:
- 2019-0183-2019-0000
- Page Start:
- 987
- Page End:
- 998
- Publication Date:
- 2019-03-15
- Subjects:
- RC beam-column joint -- 3D corner joint -- Externally bonded reinforcement on grooves (EBROG) -- X-shaped FRP -- CFRP fan -- Shear failure
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2019.01.038 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9631.xml