Test-retest reliability of elbow flexor contraction characteristics with tensiomyography for different elbow joint angles. (April 2019)
- Record Type:
- Journal Article
- Title:
- Test-retest reliability of elbow flexor contraction characteristics with tensiomyography for different elbow joint angles. (April 2019)
- Main Title:
- Test-retest reliability of elbow flexor contraction characteristics with tensiomyography for different elbow joint angles
- Authors:
- Latella, Christopher
Ruas, Cassio V.
Mesquita, Ricardo N.O.
Nosaka, Kazunori
Taylor, Janet L. - Abstract:
- Abstract: Tensiomyography (TMG) has gained popularity as a tool to quantify muscle contractile properties. However, it is unclear whether joint angle and inter-stimulus interval influence the test-retest reliability of TMG. Fifteen participants (13M/2F; 29.5 ± 7.4 y) underwent TMG recording of the biceps brachii (BB) at 10°, 45° and 90° of elbow flexion with 10 and 20 s inter-stimulus rest intervals in a randomised order on two separate days. The intra-class correlation coefficient (ICC2, 1 ) and 95% confidence interval (95%CI) were calculated for delay time (Td), contraction time (Tc), sustain time (Ts), relaxation time (Tr) and maximal displacement (Dm). Additionally, the standard error of measurement (SEM), coefficient of variation (CV) and minimal detectable change (MDC) were obtained. Across conditions the ICC2, 1 varied for each parameter (Td:0.465–0.947, Tc:0.452–0.831, Ts:0.717–0.918, Tr:0.841–0.935, Dm:0.646–0.900). CV was low for Td (2.1–3.0%), Tc (4.4–7.7%) and Ts (5.5–6.9%) but greater for Tr (10.0–15.3%) and Dm (5.8–13.1%) across conditions. Ts (∼210 ms, P < 0.001) and Dm (∼17 mm, P < 0.001) were greatest at 10° and 90°, respectively, while Td was shortest (∼22.9 ms, P = 0.002) at 10° compared to other angles. No differences were observed between inter-stimulus intervals or day. The findings are expected to help shape best practice methods for TMG use in field and research based settings.
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 45(2019)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 45(2019)
- Issue Display:
- Volume 45, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 2019
- Issue Sort Value:
- 2019-0045-2019-0000
- Page Start:
- 26
- Page End:
- 32
- Publication Date:
- 2019-04
- Subjects:
- Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2019.02.002 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9638.xml