Impact of MaxZero™ needle-free connector on the incidence of central venous catheter-related infections in surgical intensive care unit. Issue 2 (March 2019)
- Record Type:
- Journal Article
- Title:
- Impact of MaxZero™ needle-free connector on the incidence of central venous catheter-related infections in surgical intensive care unit. Issue 2 (March 2019)
- Main Title:
- Impact of MaxZero™ needle-free connector on the incidence of central venous catheter-related infections in surgical intensive care unit
- Authors:
- Clavier, Thomas
Ferguen, Mathias
Gouin, Philippe
Gillibert, André
Dusenne, Mikaël
Merle, Véronique
Veber, Benoit - Abstract:
- Abstract: Background: Central venous catheter-related infections (CRIs) are a complication of central venous catheters in intensive care unit (ICU). Some needle-free connectors have been designed to decrease CRI, but there is a lack of data concerning their impact on infection. Objectives: The objective was to explore the impact of MaxZero™ connectors (BD; Franklin Lakes, US) on CRI in ICU. Methods: Observational, pre–post design study (2011–2013 and 2014–2016) conducted in the surgical ICU of a tertiary care hospital (18 beds). Patients with a central venous catheter and a length of stay ≥48 h were included. The connectors replaced all disposable caps used on infusion stopcocks and ramps. The primary parameter was to compare the incidence of CRI between the "before" period and the "after" period. Results: A total of 1633 patients were included (789 "before" and 844 "after"). There was no difference between groups concerning the global duration of catheterisation (12.5 ± 11.5 days vs. 12.1 ± 10.9 days). There were 61 CRIs before and 28 CRIs after the introduction of connectors; the incidence of CRI in the "before" group was 20.33 CRI/year (6.18 CRI per 1000 catheter-days) vs. 9.33 CRI/year (2.73 CRI per 1000 catheter-days) in the "after" group (incidence rate ratio = 0.44; 95% confidence interval = 0.28–0.68, p < 0.001). However, after a global analysis of the 6-year period, when adjusting for seasonal effect and pre-existing linear trend, the effect was no longerAbstract: Background: Central venous catheter-related infections (CRIs) are a complication of central venous catheters in intensive care unit (ICU). Some needle-free connectors have been designed to decrease CRI, but there is a lack of data concerning their impact on infection. Objectives: The objective was to explore the impact of MaxZero™ connectors (BD; Franklin Lakes, US) on CRI in ICU. Methods: Observational, pre–post design study (2011–2013 and 2014–2016) conducted in the surgical ICU of a tertiary care hospital (18 beds). Patients with a central venous catheter and a length of stay ≥48 h were included. The connectors replaced all disposable caps used on infusion stopcocks and ramps. The primary parameter was to compare the incidence of CRI between the "before" period and the "after" period. Results: A total of 1633 patients were included (789 "before" and 844 "after"). There was no difference between groups concerning the global duration of catheterisation (12.5 ± 11.5 days vs. 12.1 ± 10.9 days). There were 61 CRIs before and 28 CRIs after the introduction of connectors; the incidence of CRI in the "before" group was 20.33 CRI/year (6.18 CRI per 1000 catheter-days) vs. 9.33 CRI/year (2.73 CRI per 1000 catheter-days) in the "after" group (incidence rate ratio = 0.44; 95% confidence interval = 0.28–0.68, p < 0.001). However, after a global analysis of the 6-year period, when adjusting for seasonal effect and pre-existing linear trend, the effect was no longer significant (adjusted incidence rate ratio = 0.57; 95% confidence interval = 0.24–1.35, p = 0.20). Conclusions: Our results do not allow us to conclude to a potential beneficial effect of MaxZero™ on CRI but are compatible with its prolonged and safe use in ICU. Only future prospective works will be able to confirm the value of these connectors for CRI prevention. … (more)
- Is Part Of:
- Australian critical care. Volume 32:Issue 2(2019)
- Journal:
- Australian critical care
- Issue:
- Volume 32:Issue 2(2019)
- Issue Display:
- Volume 32, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2019-0032-0002-0000
- Page Start:
- 107
- Page End:
- 111
- Publication Date:
- 2019-03
- Subjects:
- Catheter-related infection -- Infusions -- Intravenous -- Intensive care unit -- Central venous catheters -- Vascular access devices -- Infection control
Intensive care nursing -- Periodicals
Intensive care nursing -- Australia -- Periodicals
Electronic journals
616.028 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10367314 ↗
http://www.informit.com.au/show.asp?id=MEDITEXT ↗
http://search.informit.com.au/search;res=MEDITEXT;search=IS=1036-7314 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.aucc.2018.03.003 ↗
- Languages:
- English
- ISSNs:
- 1036-7314
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1798.264300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9622.xml