Analysis of lipase activity in duodenal juice. Comparison of an automated spectrophotometric assay to a fluorometric microplate assay, and factors affecting sample stability. (2nd November 2018)
- Record Type:
- Journal Article
- Title:
- Analysis of lipase activity in duodenal juice. Comparison of an automated spectrophotometric assay to a fluorometric microplate assay, and factors affecting sample stability. (2nd November 2018)
- Main Title:
- Analysis of lipase activity in duodenal juice. Comparison of an automated spectrophotometric assay to a fluorometric microplate assay, and factors affecting sample stability
- Authors:
- Tjora, Erling
Erchinger, Friedemann
Engjom, Trond
Aksnes, Lage
Dimcevski, Georg
Gudbrandsen, Oddrun Anita - Abstract:
- Abstract: Background: Direct pancreas function testing (DPFT) has been regarded as gold standard for assessment of exocrine pancreas function. One of the outcomes from DPFT is pancreatic lipase activity in duodenal juice, but no standard assay for measuring pancreas lipase activity in duodenal juice exists. Aims: To optimize and evaluate an autoanalyzer assay for measuring lipase activity in duodenal juice. Methods: We used samples of duodenal juice from our biobank, collected through a short endoscopic secretin test in patients with suspected exocrine pancreas insufficiency. Samples were analyzed on a Cobas autoanalyzer (Roche Diagnostics), using a colorimetric, kinetic enzyme activity assay. We compared stability of samples diluted in saline to samples diluted in 3-( N -morpholino) propane sulfonic acid (MOPS) buffer added bovine serum albumin (BSA). Results from the Cobas assay were compared to Confluolip method, a fluorometric, kinetic enzyme assay, modified to fit into a microplate setting. Results: We tested the stability of 54 samples from 21 patients. Diluting samples with MOPS buffer added BSA gave stable results, and was superior to diluting samples in saline. We compared the two assays in 50 samples from 20 patients and found a good correlation between the two assays ( r = 0.91, p < .001). There was a significant proportional bias between the two assays, but no significant systematic bias. Conclusion: Pancreatic lipase activity in duodenal juice samples dilutedAbstract: Background: Direct pancreas function testing (DPFT) has been regarded as gold standard for assessment of exocrine pancreas function. One of the outcomes from DPFT is pancreatic lipase activity in duodenal juice, but no standard assay for measuring pancreas lipase activity in duodenal juice exists. Aims: To optimize and evaluate an autoanalyzer assay for measuring lipase activity in duodenal juice. Methods: We used samples of duodenal juice from our biobank, collected through a short endoscopic secretin test in patients with suspected exocrine pancreas insufficiency. Samples were analyzed on a Cobas autoanalyzer (Roche Diagnostics), using a colorimetric, kinetic enzyme activity assay. We compared stability of samples diluted in saline to samples diluted in 3-( N -morpholino) propane sulfonic acid (MOPS) buffer added bovine serum albumin (BSA). Results from the Cobas assay were compared to Confluolip method, a fluorometric, kinetic enzyme assay, modified to fit into a microplate setting. Results: We tested the stability of 54 samples from 21 patients. Diluting samples with MOPS buffer added BSA gave stable results, and was superior to diluting samples in saline. We compared the two assays in 50 samples from 20 patients and found a good correlation between the two assays ( r = 0.91, p < .001). There was a significant proportional bias between the two assays, but no significant systematic bias. Conclusion: Pancreatic lipase activity in duodenal juice samples diluted in MOPS buffer added BSA is stable for one hour at room temperature. Quantification of lipase activity in duodenal juice using a standard automated activity assay has comparable accuracy to a manual fluorometric method. … (more)
- Is Part Of:
- Scandinavian journal of gastroenterology. Volume 53:Number 10/11(2018)
- Journal:
- Scandinavian journal of gastroenterology
- Issue:
- Volume 53:Number 10/11(2018)
- Issue Display:
- Volume 53, Issue 10/11 (2018)
- Year:
- 2018
- Volume:
- 53
- Issue:
- 10/11
- Issue Sort Value:
- 2018-0053-NaN-0000
- Page Start:
- 1206
- Page End:
- 1211
- Publication Date:
- 2018-11-02
- Subjects:
- Exocrine pancreas function testing -- duodenal juice -- pancreas triglyceride lipase -- kinetic enzyme assay
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33 - Journal URLs:
- http://informahealthcare.com/loi/gas ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365521.2018.1518481 ↗
- Languages:
- English
- ISSNs:
- 0036-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.507000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9618.xml