A comparative study of identical VMAT plans with and without jaw tracking technique. (8th September 2016)
- Record Type:
- Journal Article
- Title:
- A comparative study of identical VMAT plans with and without jaw tracking technique. (8th September 2016)
- Main Title:
- A comparative study of identical VMAT plans with and without jaw tracking technique
- Authors:
- Wu, Hao
Jiang, Fan
Yue, Haizhen
Hu, Qiaoqiao
Zhang, Jian
Liu, Zhuolun
Gong, Jian
Li, Sha
Geng, Jianhao
Zhang, Yibao - Abstract:
- Abstract : The unwanted radiation transmission through the multileaf collimators could be reduced by the jaw tracking technique which is commercially available on Varian TrueBeam accelerators. On the basis of identical plans, this study aims to investigate the dosimetric impact of jaw tracking on the volumetric‐modulated arc therapy (VMAT) plans. Using Eclipse treatment planning system (TPS), 40 jaw‐tracking VMAT plans with various tumor volumes and shapes were optimized. Fixed jaw plans were created by editing the jaw coordinates of the jaw‐tracking plans while other parameters were identical. The deliverability of this artificial modification was verified using COMPASS system via three‐dimentional gamma analysis between the measurement‐based reconstruction and the TPS‐calculated dose distribution. Dosimetric parameters of dose‐volume histogram (DVH) were compared to assess the improvement of dose sparing for organs at risk (OARs) in jaw‐tracking plans. COMPASS measurements demonstrated that over 96.9% of structure volumes achieved gamma values less than 1.00 at criteria of 3 mm / 3 % . The reduction magnitudes of maximum and mean dose to various OARs ranged between 0.06 % ∼ 6.76 % ( 0.04 ∼ 7.29 Gy ) and 0.09 % ∼ 7.81 % ( 0.02 ∼ 2.78 Gy ), respectively, using jaw tracking, agreeing with the disparities of radiological characteristics between MLC and jaws. Jaw tracking does not change the delivery efficiency and total monitor units. The dosimetric comparison of VMATAbstract : The unwanted radiation transmission through the multileaf collimators could be reduced by the jaw tracking technique which is commercially available on Varian TrueBeam accelerators. On the basis of identical plans, this study aims to investigate the dosimetric impact of jaw tracking on the volumetric‐modulated arc therapy (VMAT) plans. Using Eclipse treatment planning system (TPS), 40 jaw‐tracking VMAT plans with various tumor volumes and shapes were optimized. Fixed jaw plans were created by editing the jaw coordinates of the jaw‐tracking plans while other parameters were identical. The deliverability of this artificial modification was verified using COMPASS system via three‐dimentional gamma analysis between the measurement‐based reconstruction and the TPS‐calculated dose distribution. Dosimetric parameters of dose‐volume histogram (DVH) were compared to assess the improvement of dose sparing for organs at risk (OARs) in jaw‐tracking plans. COMPASS measurements demonstrated that over 96.9% of structure volumes achieved gamma values less than 1.00 at criteria of 3 mm / 3 % . The reduction magnitudes of maximum and mean dose to various OARs ranged between 0.06 % ∼ 6.76 % ( 0.04 ∼ 7.29 Gy ) and 0.09 % ∼ 7.81 % ( 0.02 ∼ 2.78 Gy ), respectively, using jaw tracking, agreeing with the disparities of radiological characteristics between MLC and jaws. Jaw tracking does not change the delivery efficiency and total monitor units. The dosimetric comparison of VMAT plans with and without jaw tracking confirms the physics hypotheses that reduced transmission through tracking jaws will reduce doses to OARs without sacrificing the target dose coverage because it is meant to be covered by radiation beams going through the opening. PACS number(s): 87.55.de, 87.55.dk … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 5(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 5(2016)
- Issue Display:
- Volume 17, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2016-0017-0005-0000
- Page Start:
- 133
- Page End:
- 141
- Publication Date:
- 2016-09-08
- Subjects:
- jaw tracking -- VMAT -- MLC transmission -- treatment planning -- optimization
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i5.6252 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9617.xml