103Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design. Issue 1 (2nd January 2014)
- Record Type:
- Journal Article
- Title:
- 103Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design. Issue 1 (2nd January 2014)
- Main Title:
- 103Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design
- Authors:
- Rivard, Mark J.
Reed, Joshua L.
DeWerd, Larry A. - Abstract:
- Abstract : Purpose: : A new type of 103 Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains 103 Pd and Au radio‐opaque marker(s), all contained within low‐ Z eff organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional 103 Pd seeds. Methods: : The MCNP5 radiation transport code was used to estimate air‐kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG‐43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: : The normalized air‐kerma rate was not highly dependent on L or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L . The air‐kerma strength was also weakly dependent on L . The uncertainty analysisAbstract : Purpose: : A new type of 103 Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains 103 Pd and Au radio‐opaque marker(s), all contained within low‐ Z eff organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional 103 Pd seeds. Methods: : The MCNP5 radiation transport code was used to estimate air‐kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG‐43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: : The normalized air‐kerma rate was not highly dependent on L or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L . The air‐kerma strength was also weakly dependent on L . The uncertainty analysis established a standard uncertainty of 1.3% for the dose‐rate constant Λ, where the largest contributors were μ en / ρ and μ / ρ . The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to 103 Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional 103 Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm 3 for any of the examined source combinations. Conclusions: : By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti‐encapsulated 103 Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo‐based radiation transport simulations. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 1(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 1(2014)
- Issue Display:
- Volume 41, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2014-0041-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-01-02
- Subjects:
- Therapeutic applications, including brachytherapy -- Dosimetry/exposure assessment -- Radioactive sources -- Monte Carlo methods
biological organs -- biological tissues -- biomedical equipment -- brachytherapy -- dosimetry -- encapsulation -- gold -- Monte Carlo methods -- palladium -- phantoms -- polymers -- radioactive sources -- shielding -- titanium -- water
103Pd -- polymer -- brachytherapy -- dosimetry -- Monte Carlo methods
Radiation therapy -- Radioactive sources -- Scintigraphy -- Radioactive sources other than neutron sources (radioactive dressings A61M36/14)
Dosimetry -- Photons -- Gold -- Infrared sources -- Brachytherapy -- Polymers -- Anisotropy -- Radioactivity -- Medical treatment planning -- Monte Carlo methods
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4856015 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9616.xml