Is There Any Benefit of Neuromonitoring during Descending and Thoracoabdominal Aortic Aneurysm Repair?. Issue 5 (September 2015)
- Record Type:
- Journal Article
- Title:
- Is There Any Benefit of Neuromonitoring during Descending and Thoracoabdominal Aortic Aneurysm Repair?. Issue 5 (September 2015)
- Main Title:
- Is There Any Benefit of Neuromonitoring during Descending and Thoracoabdominal Aortic Aneurysm Repair?
- Authors:
- Fok, Matthew
Jafarzadeh, Fatemeh
Sancho, Elena
Abello, David
Rimmer, Lara
Howard, Callum
Kennedy, Tom
Hammoud, Ibrahim
Bashir, Mohamad - Abstract:
- Objective: Paraplegia remains the most feared and a devastating complication after descending and thoracoabdominal aneurysm operative repair (DTA and TAAAR). Neuromonitoring, particularly use of motor-evoked potentials (MEPs), for this surgery has gained popularity. However, ambiguity remains regarding its use and benefit. We systematically reviewed the literature to assess the benefit and applicability of neuromonitoring in DTA and TAAAR. Methods: Electronic searches were performed on 4 major databases from inception until February 2014 to identify relevant studies. Eligibility decisions, method quality, data extraction, and analysis were performed according to predefined clinical criteria and end points. Results: Among the studies matching our inclusion criteria, 1297 patients had MEP monitoring during DTA and TAAAR. In-hospital mortality was low (6.9% ± 3.6). Immediate neurological deficit was low (3.5% ± 2.6). In one third of patients (30.4% ± 14.2), the MEPs dropped below threshold, which were 30.4% and 29.4% with threshold levels of 75% and 50%, respectively. A range of surgical techniques were applied after reduction in MEPs. Most patients whose MEPs dropped and remained below threshold had immediate permanent neurological deficit (92.0% ± 23.6). Somatosensory-evoked potentials were reported in one third of papers with little association between loss of somatosensory-evoked potentials and permanent neurological deficit (16.7% ± 28.9%). Conclusions: We demonstrate thatObjective: Paraplegia remains the most feared and a devastating complication after descending and thoracoabdominal aneurysm operative repair (DTA and TAAAR). Neuromonitoring, particularly use of motor-evoked potentials (MEPs), for this surgery has gained popularity. However, ambiguity remains regarding its use and benefit. We systematically reviewed the literature to assess the benefit and applicability of neuromonitoring in DTA and TAAAR. Methods: Electronic searches were performed on 4 major databases from inception until February 2014 to identify relevant studies. Eligibility decisions, method quality, data extraction, and analysis were performed according to predefined clinical criteria and end points. Results: Among the studies matching our inclusion criteria, 1297 patients had MEP monitoring during DTA and TAAAR. In-hospital mortality was low (6.9% ± 3.6). Immediate neurological deficit was low (3.5% ± 2.6). In one third of patients (30.4% ± 14.2), the MEPs dropped below threshold, which were 30.4% and 29.4% with threshold levels of 75% and 50%, respectively. A range of surgical techniques were applied after reduction in MEPs. Most patients whose MEPs dropped and remained below threshold had immediate permanent neurological deficit (92.0% ± 23.6). Somatosensory-evoked potentials were reported in one third of papers with little association between loss of somatosensory-evoked potentials and permanent neurological deficit (16.7% ± 28.9%). Conclusions: We demonstrate that MEPs are useful at predicting paraplegia in patients who lose their MEPs and do not regain them intraoperatively. To date, there is no consensus regarding the applicability and use of MEPs. Current evidence does not mandate or support MEP use. … (more)
- Is Part Of:
- Innovations. Volume 10:Issue 5(2015:Sep./Oct.)
- Journal:
- Innovations
- Issue:
- Volume 10:Issue 5(2015:Sep./Oct.)
- Issue Display:
- Volume 10, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 5
- Issue Sort Value:
- 2015-0010-0005-0000
- Page Start:
- 342
- Page End:
- 348
- Publication Date:
- 2015-09
- Subjects:
- Thoracic aortic aneurysm -- Thoracoabdominal aortic aneurysm repair -- Neuromonitoring -- Motor-evoked potentials -- Somatosensory-evoked potentials
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/155698451501000509 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9602.xml