Electronic patient identification for sample labeling reduces wrong blood in tube errors. Issue 3 (14th December 2018)
- Record Type:
- Journal Article
- Title:
- Electronic patient identification for sample labeling reduces wrong blood in tube errors. Issue 3 (14th December 2018)
- Main Title:
- Electronic patient identification for sample labeling reduces wrong blood in tube errors
- Authors:
- Kaufman, Richard M.
Dinh, Anh
Cohn, Claudia S.
Fung, Mark K.
Gorlin, Jed
Melanson, Stacy
Murphy, Michael F.
Ziman, Alyssa
Elahie, Allahna L.
Chasse, Danielle
Degree, Lynsi
Dunbar, Nancy M.
Dzik, Walter H.
Flanagan, Peter
Gabert, Kimberly
Ipe, Tina S.
Jackson, Bryon
Lane, Debra
Raspollini, Elisabetta
Ray, Charles
Sharon, Yudit
Ellis, Martin
Selleng, Kathleen
Staves, Julie
Yu, Philip
Zeller, Michelle
Yazer, Mark - Abstract:
- Abstract : BACKGROUND: Wrong blood in tube (WBIT) errors are a preventable cause of ABO‐mismatched RBC transfusions. Electronic patient identification systems (e.g., scanning a patient's wristband barcode before pretransfusion sample collection) are thought to reduce WBIT errors, but the effectiveness of these systems is unclear. STUDY DESIGN AND METHODS: Part 1: Using retrospective data, we compared pretransfusion sample WBIT rates at hospitals using manual patient identification (n = 16 sites; >1.6 million samples) with WBIT rates at hospitals using electronic patient identification for some or all sample collections (n = 4 sites; >0.5 million samples). Also, we compared WBIT rates after implementation of electronic patient identification with preimplementation WBIT rates. Causes and frequencies of WBIT errors were evaluated at each site. Part 2: Transfusion service laboratories (n = 18) prospectively typed mislabeled (rejected) samples (n = 2844) to determine WBIT rates among samples with minor labeling errors. RESULTS: Part 1: The overall unadjusted WBIT rate at sites using manual patient identification was 1:10, 110 versus 1:35, 806 for sites using electronic identification (p < 0.0001). Correcting for repeat samples and silent WBIT errors yielded overall adjusted WBIT rates of 1:3046 for sites using manual identification and 1:14, 606 for sites using electronic identification (p < 0.0001), with wide variation among individual sites. Part 2: The unadjusted WBIT rateAbstract : BACKGROUND: Wrong blood in tube (WBIT) errors are a preventable cause of ABO‐mismatched RBC transfusions. Electronic patient identification systems (e.g., scanning a patient's wristband barcode before pretransfusion sample collection) are thought to reduce WBIT errors, but the effectiveness of these systems is unclear. STUDY DESIGN AND METHODS: Part 1: Using retrospective data, we compared pretransfusion sample WBIT rates at hospitals using manual patient identification (n = 16 sites; >1.6 million samples) with WBIT rates at hospitals using electronic patient identification for some or all sample collections (n = 4 sites; >0.5 million samples). Also, we compared WBIT rates after implementation of electronic patient identification with preimplementation WBIT rates. Causes and frequencies of WBIT errors were evaluated at each site. Part 2: Transfusion service laboratories (n = 18) prospectively typed mislabeled (rejected) samples (n = 2844) to determine WBIT rates among samples with minor labeling errors. RESULTS: Part 1: The overall unadjusted WBIT rate at sites using manual patient identification was 1:10, 110 versus 1:35, 806 for sites using electronic identification (p < 0.0001). Correcting for repeat samples and silent WBIT errors yielded overall adjusted WBIT rates of 1:3046 for sites using manual identification and 1:14, 606 for sites using electronic identification (p < 0.0001), with wide variation among individual sites. Part 2: The unadjusted WBIT rate among mislabeled (rejected) samples was 1:71 (adjusted WBIT rate, 1:28). CONCLUSION: In this study, using electronic patient identification at the time of pretransfusion sample collection was associated with approximately fivefold fewer WBIT errors compared with using manual patient identification. WBIT rates were high among mislabeled (rejected) samples, confirming that rejecting samples with even minor labeling errors helps mitigate the risk of ABO‐incompatible transfusions. Abstract : See article on page 899–902, in this issue … (more)
- Is Part Of:
- Transfusion. Volume 59:Issue 3(2019)
- Journal:
- Transfusion
- Issue:
- Volume 59:Issue 3(2019)
- Issue Display:
- Volume 59, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 59
- Issue:
- 3
- Issue Sort Value:
- 2019-0059-0003-0000
- Page Start:
- 972
- Page End:
- 980
- Publication Date:
- 2018-12-14
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.15102 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9584.xml