Multicriteria evaluation and optimization of the ultrasonic sealing performance based on design of experiments and response surface methodology. Issue 4 (20th February 2019)
- Record Type:
- Journal Article
- Title:
- Multicriteria evaluation and optimization of the ultrasonic sealing performance based on design of experiments and response surface methodology. Issue 4 (20th February 2019)
- Main Title:
- Multicriteria evaluation and optimization of the ultrasonic sealing performance based on design of experiments and response surface methodology
- Authors:
- D'huys, Karlien
Bamps, Bram
Peeters, Roos
De Ketelaere, Bart - Abstract:
- Abstract : Proper closure is an essential packaging quality aspect and can, amongst others, be achieved with ultrasonic sealing. The ultrasonic sealing performance depends on the film type, and the seal settings, such as seal time, applied force and ultrasonic amplitude. Because these parameters are less intuitive than heat seal parameters and optimal settings are undefined for many films, this work presents an efficient approach to evaluate the effect of these settings on the ultrasonic sealing performance. An experimental design defines the experiments to perform. A response surface methodology is then used to model the relation between seal settings and sealing performance. Based on these models, the seal settings are optimized. As there are several criteria to express sealing performance, single‐criteria and multicriteria optimizations are described. The approach was illustrated for a polyethylene terephthalate/linear low‐density polyethylene‐C4 film. The seal settings were optimized to obtain high seal strength, limited ultrasonic horn displacement, and low seal energy. The optimum settings were 0.1 seconds (seal time), 4.32 N/mm (force), and 28.75 μm (amplitude). The predicted optimum strength, horn displacement, and energy were 2.32 N/mm, 40 μm, and 11.66 J, respectively. Besides the optimum, the seal window is also of interest. A broad seal window ensures sufficient seal strength for a wide range of settings. For the polyethylene terephthalate/linear low‐densityAbstract : Proper closure is an essential packaging quality aspect and can, amongst others, be achieved with ultrasonic sealing. The ultrasonic sealing performance depends on the film type, and the seal settings, such as seal time, applied force and ultrasonic amplitude. Because these parameters are less intuitive than heat seal parameters and optimal settings are undefined for many films, this work presents an efficient approach to evaluate the effect of these settings on the ultrasonic sealing performance. An experimental design defines the experiments to perform. A response surface methodology is then used to model the relation between seal settings and sealing performance. Based on these models, the seal settings are optimized. As there are several criteria to express sealing performance, single‐criteria and multicriteria optimizations are described. The approach was illustrated for a polyethylene terephthalate/linear low‐density polyethylene‐C4 film. The seal settings were optimized to obtain high seal strength, limited ultrasonic horn displacement, and low seal energy. The optimum settings were 0.1 seconds (seal time), 4.32 N/mm (force), and 28.75 μm (amplitude). The predicted optimum strength, horn displacement, and energy were 2.32 N/mm, 40 μm, and 11.66 J, respectively. Besides the optimum, the seal window is also of interest. A broad seal window ensures sufficient seal strength for a wide range of settings. For the polyethylene terephthalate/linear low‐density polyethylene‐C4 film, a strength of ≥90% of the optimum was obtained for 39% of the input combinations within the design space. The presented approach is widely applicable (other films and sealing processes) since it is flexible in the input parameters, design, and responses. Abstract : This work presents an efficient approach to evaluate the effect of seal settings on the ultrasonic sealing performance. A design of experiments and response surface methodology, allowing for both single‐criteria and multicriteria optimization, was used for this purpose. The approach was illustrated for a polyethylene terephthalate/linear low‐density polyethylene‐C4 film. … (more)
- Is Part Of:
- Packaging technology and science. Volume 32:Issue 4(2019)
- Journal:
- Packaging technology and science
- Issue:
- Volume 32:Issue 4(2019)
- Issue Display:
- Volume 32, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2019-0032-0004-0000
- Page Start:
- 165
- Page End:
- 174
- Publication Date:
- 2019-02-20
- Subjects:
- design of experiments -- multicriteria seal optimization -- polyolefin packaging -- response surface methodology -- ultrasonic sealing
Packaging -- Periodicals
688.8 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/pts.2425 ↗
- Languages:
- English
- ISSNs:
- 0894-3214
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.018500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9590.xml