18F-FDG PET in the Diagnosis of Vascular Prosthetic Graft Infection: A Diagnostic Test Accuracy Meta-Analysis. (February 2019)
- Record Type:
- Journal Article
- Title:
- 18F-FDG PET in the Diagnosis of Vascular Prosthetic Graft Infection: A Diagnostic Test Accuracy Meta-Analysis. (February 2019)
- Main Title:
- 18F-FDG PET in the Diagnosis of Vascular Prosthetic Graft Infection: A Diagnostic Test Accuracy Meta-Analysis
- Authors:
- Rojoa, Djamila
Kontopodis, Nikos
Antoniou, Stavros A.
Ioannou, Christos V.
Antoniou, George A. - Abstract:
- Abstract : Background: For the diagnosis of vascular prosthetic graft infection (VPGI), an intra-operative peri-graft biopsy is often required. Controversy exists regarding the use of imaging techniques in the diagnostic process. This study aimed to evaluate the diagnostic accuracy of 18-fluorine fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in VPGI. Methods: A systematic search of electronic databases was conducted, applying a combination of free text and controlled vocabulary searches adapted to thesaurus headings, search operators, and limits to identify studies assessing the use of 18F-FDG PET in the diagnosis of VPGI. A meta-analysis was conducted using a mixed effects logistic regression bivariate model. Results: Twelve studies were identified reporting a total of 433 prostheses, of which 202 were proven to be infected. Analysis of PET scan was performed using five different methods: graded uptake, focal uptake, maximum standardised uptake value (SUVmax), tissue to background ratio (TBR), and dual time point (DTP). The pooled estimates for sensitivity and specificity for graded uptake were 0.89 (95% CI 0.73–0.96) and 0.61 (95% CI 0.48–0.74), respectively; they were 0.93 (95% CI 0.83–0.97) and 0.78 (95% CI 0.53–0.92) for focal uptake; 0.98 (95% CI 0.42–0.99) and 0.80 (95% CI 0.70–0.88) for SUVmax; 0.57 (95% CI 0.39–0.73) and 0.76 (95% CI 0.64–0.85) for TBR; and 1.00 (95% CI 0.48–1.00) and 0.88 (95% CI 0.68–0.97) for DTP. Sensitivity analysis includingAbstract : Background: For the diagnosis of vascular prosthetic graft infection (VPGI), an intra-operative peri-graft biopsy is often required. Controversy exists regarding the use of imaging techniques in the diagnostic process. This study aimed to evaluate the diagnostic accuracy of 18-fluorine fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in VPGI. Methods: A systematic search of electronic databases was conducted, applying a combination of free text and controlled vocabulary searches adapted to thesaurus headings, search operators, and limits to identify studies assessing the use of 18F-FDG PET in the diagnosis of VPGI. A meta-analysis was conducted using a mixed effects logistic regression bivariate model. Results: Twelve studies were identified reporting a total of 433 prostheses, of which 202 were proven to be infected. Analysis of PET scan was performed using five different methods: graded uptake, focal uptake, maximum standardised uptake value (SUVmax), tissue to background ratio (TBR), and dual time point (DTP). The pooled estimates for sensitivity and specificity for graded uptake were 0.89 (95% CI 0.73–0.96) and 0.61 (95% CI 0.48–0.74), respectively; they were 0.93 (95% CI 0.83–0.97) and 0.78 (95% CI 0.53–0.92) for focal uptake; 0.98 (95% CI 0.42–0.99) and 0.80 (95% CI 0.70–0.88) for SUVmax; 0.57 (95% CI 0.39–0.73) and 0.76 (95% CI 0.64–0.85) for TBR; and 1.00 (95% CI 0.48–1.00) and 0.88 (95% CI 0.68–0.97) for DTP. Sensitivity analysis including studies that investigated the diagnostic accuracy of PET combined with computed tomography (CT) showed higher sensitivity and specificity for focal uptake, graded uptake, and SUVmax than 18F-FDG PET alone. Conclusions: This meta-analysis suggests that 18F-FDG PET has a high sensitivity in diagnosing VPGI and its accuracy can be further increased by combining PET with CT. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 57:Number 2(2019)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 57:Number 2(2019)
- Issue Display:
- Volume 57, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 57
- Issue:
- 2
- Issue Sort Value:
- 2019-0057-0002-0000
- Page Start:
- 292
- Page End:
- 301
- Publication Date:
- 2019-02
- Subjects:
- Vascular graft -- Infection -- Positron-emission tomography -- PET -- Diagnostic accuracy
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2018.08.040 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9562.xml